LED stands for “Light Emitting Diode” and is a kind of semiconductor, which emits light when electrified.
In other words, the LED emits light by itself and requires no filaments like incandescent lamps, which is fundamentally different from conventional light sources.
LED has long life span, however, deterioration of the sealing materials will reduce its light efficiency.
A Light Emitting Diode (LED) light source is a semiconductor. Light emitting diodes (LEDs) are used as indicator lamps in many devices, and are increasingly used for lighting. Introduced as an electronic component in the handy LED.
Researchers from around the world gathered at the Materials Research Society fall meeting in Boston last week to discuss the progress they're making in using quantum dots to enhance the color and efficiency of light-emitting diodes (LEDs). Today's white-light LEDs consist of a blue-emitting LED coated with a phosphor that is excited by the LED and emits a yellow or orange light. The combination of blue and yellow produces a cold white light lacking in red photons,
Factors influencing the deterioration of packaging resin material: -
Heat
High ambient temperature and generated heat by high electric current give rise to resin deterioration.
Light
Bigger spectrum energy increases resin deterioration.
Blue spectrum has bigger energy compared with red spectrum, therefore life span of blue color LED is shorter than others.
light-emitting diode n. LED. I-V diagram for a diode an LED will begin to emit light when the on-voltage XLamp XP-G LED chip emitting Cool White light) and are being (.... quot; led light bulbs led lamps -- Provider of led light bulbs, LED components and lighting technology. LC LED offers Light Emitting Diode (L.E.D.) base systems solution for your every day consumer (.... lightemitting diodes led learning activity -- Copyright © Wisc-Online. Title: Light-Emitting Diodes (LED) Author: Patrick Hoppe. Developer: Chad Blohowiak. Facebook. Now Available - Click Here to Purchase (.... special report business of green small british company develops -- Light emitting diode, or LED, lights are becoming popular because of their low energy use, long life and versatility, yet they present several problems — ranging from a risk of (.... light emitting diodes -- A Light Emitting Diode (LED) light source is a semiconductor. Light emitting diodes (LEDs) are used as indicator lamps in many devices, and are increasingly used for lighting. (.... light emitting diodes led -- Basic car audio technical information with plenty of graphics. This site starts with the most basic information so that everyone will be able to understand the more advanced topics (.... lightemittingdiodesdotorg home page -- Buy the book Light Emitting Diodes by E. F. Schubert: 2006 LED book pictures (80 MB).pdf Homepage of E. Fred Schubert National Compound Semiconductor Roadmap Compund (.... led wikipedia the free encyclopedia -- LEd (formerly LaTeX Editor) is a TeX / LaTeX editing software working under Microsoft Windows. It is a freeware product. See also. Comparison of TeX editors (.... howstuffworks quot;how light emitting diodes workquot; -- Light emitting diodes form the numbers on digital clocks, send data from remote controls and light up traffic signals. Find out how LEDs work. (.... led light emitting diode lights light bulbs etc inc -- Light Bulbs Etc, Inc. carries LED (Light Emitting Diode) Lights, including LED (Light Emitting Diode) Night Lights. These LED (Light Emitting Diode) Night Lights are low cost (.... lightemitting diode wikipedia the free encyclopedia -- A light-emitting diode (LED) (pronounced /ˌɛl.iːˈdiː/ [1], or just /lɛd/) is a semiconductor light source. LEDs are used as indicator lamps in many devices,
Showing posts with label Terms. Show all posts
Showing posts with label Terms. Show all posts
Thursday, December 10, 2009
Wednesday, May 14, 2008
what is Illuminance E ?
The unit of measurement is the lux [lx]: E = F / A F = luminous flux in lumenensA = area illuminated in m2 Illuminance E is the ratio between the luminous flux and the area to be illuminated. An illuminance of 1 lx occurs when a luminous flux of 1 lm falls evenly on an area of 1 m². Based on the definitions for illuminance luminous intensity and solid angle W = A/r2, we obtain the following formula for illuminance: E = I / r2Photometric inverse square law r = distance of the light source to the object in mA = area illuminated in m2I = luminous intensity in Candela It is assumed that the light falls perpendicular to the surface it illuminates. If the surface is at an angle a then E = I/r2 must be multiplied by cos a.
What is HMI lamps
HMI lamps are metal halide lamps with an increased load on the bulb wall and very short electrode gaps to improve luminous efficacy and colour rendering, at the expense however of lamp life. These lamps are ideal for applications such as theatre lighting, endoscopy, filming and TV recordings under daylight conditions (colour temperature
= 6000K).These lamps range in wattage from 200 W to 18 kW.
what is Halogen cycle
Halogen cycle The main characteristics of an incandescent lamp, namely its luminous efficacy and service life, are determined to a large extent by the filament temperature. The higher the filament temperature, the higher the luminous efficacy but the shorter the life of the lamp. This reduction in the life of the lamp is a consequence of the rate at which tungsten evaporates from the filament. This rate increases rapidly with increasing temperature. Not only does it blacken the inside of the bulb, it causes the filament ultimately to burn out. This blackening of the bulb can be effectively countered by adding halogens to the filler gas to prevent evaporated tungsten from depositing on the bulb wall by a "halogen cycle process". The tungsten that evaporates from the filament during normal operation migrates towards the bulb wall by diffusion or thermal convection In the temperature region <1400>1400 K) where they dissociate back to tungsten and halogen, leaving the halogen to repeat the cycle. Some of the tungsten is transported back to the filament, but not to its original location. The "normal halogen cycle" therefore merely prevents the bulb from blackening, it does not extend the life of the lamp. The lamp comes to the end of its life when the filament melts at one of its hot spots.
Friday, May 9, 2008
Pulse ignition systems
For HS, HI and C-HI lamps - PZ 1000 K / PZ 1000 K P20 For high-pressure sodium lamps (HS), metal halide lamps (HI) 35 -1000 W and ceramic discharge tube lamps (C-HI) 35 - 400 W Ignition voltage: 1.8 - 2.3 kV or 4.0 - 5.0 kV, respectively No. of pulses: 2 per mains period Load capacitance: 20 -1000 pF Suitable ballast types: NaHJ ... PZ/PZT with special winding tapping point, whose position is determined by the magnitude of the ignition voltage

For HI lamps - PZI 1000/1 K and PZI 2000/400 V 1.2 kV For metal halide lamps (HI) with an ignition voltage up to 0.9 kV or 1.3 kV, respectively. No. of pulses: 1per mains period Load capacitance: max. 10,000 pF Suitable ballast models: Q...

For HI lamps - PZI 1000/1 K and PZI 2000/400 V 1.2 kV For metal halide lamps (HI) with an ignition voltage up to 0.9 kV or 1.3 kV, respectively. No. of pulses: 1per mains period Load capacitance: max. 10,000 pF Suitable ballast models: Q...
Mandatory regulations of HID Ballast
DIN VDE 0100
Regulations for the installation of power current facilities with rated voltages of up to 1000 V
EN 60598-1
Luminaires - part 1: general requirements and tests
EN 61347-1
Devices for lamps - part 1: general and safety requirements
EN 61347-2-9
Devices for lamps - part 2 - 9: special requirements for ballasts for discharge lamps (except fluorescent lamps)
EN 60923
Ballasts for discharge lamps - performance requirements
EN 55015
Maximum values and methods of measurement for RFI suppression in electrical lighting installations and similar electrical appliances
EN 61000-3-2
Electromagnetic Compatibility (EMC) - part 3: maximum values - main section part 2: maximum values for mains harmonics (device input current up to and including 16 A per conductor)
EN 61547
Installations for general illumination purposes - EMC immunity requirements
Click on the image to get a PDF-file with the assembly instructions of electronic converters.
Regulations for the installation of power current facilities with rated voltages of up to 1000 V
EN 60598-1
Luminaires - part 1: general requirements and tests
EN 61347-1
Devices for lamps - part 1: general and safety requirements
EN 61347-2-9
Devices for lamps - part 2 - 9: special requirements for ballasts for discharge lamps (except fluorescent lamps)
EN 60923
Ballasts for discharge lamps - performance requirements
EN 55015
Maximum values and methods of measurement for RFI suppression in electrical lighting installations and similar electrical appliances
EN 61000-3-2
Electromagnetic Compatibility (EMC) - part 3: maximum values - main section part 2: maximum values for mains harmonics (device input current up to and including 16 A per conductor)
EN 61547
Installations for general illumination purposes - EMC immunity requirements
Click on the image to get a PDF-file with the assembly instructions of electronic converters.
Thursday, May 8, 2008
Fluorescent lamps
Fluorescent lamps are low pressure gas discharge lamps in which the invisible UV radiation generated by the discharge is converted into visible radiation (i.e. light) with the aid of phosphors. (Principle of fluorescence) There are tubular, ring-shaped and U-shaped fluorescent lamps and also compact fluorescent lamps. The tube diameter is often expressed in eighths of an inch (e.g. T5 = 5/8'' = 16 mm). In the lamp catalogues, diameters are also given in millimetres (e.g. 16 mm for T5 lamps). Most lamps are internationally standardized. Like all discharge lamps, fluorescent lamps cannot be operated directly on mains voltage because of their negative internal resistance characteristics. Suitable control gear between the mains supply and the lamp, limits and control the lamp current and ensures reliable starting under specific conditions. Fluorescent lamps have various operating modes, depending on the way in which the electrodes are brought up to the temperature:
Current-controlled preheating in switch-start mode, preferred in countries with a high mains voltage (200 V or more). Used in most electronic control gear (ECG).
Voltage-controlled preheating with additional transformer for "rapid start" mode.
No preheating (cold start, used for example with slimline lamps). This type of starting reduces the lamp life more than any other type and is therefore not recommended for systems with frequent on/off switching.
Electronic control gear (ECG) converts the mains frequency into a high frequency supply in the region of 35 to 50 kHz. As a result, the 100 Hz flicker that may appear as a stroboscopic effect, for example with rotating machines, is much less noticeable or virtually eliminated. Another advantage of ECG operation is the additional energy savings of around 25% for the same luminous flux, comprising:
10% high luminous efficacy from the fluorescent lamp operating at a high frequency
Much lower losses in the ECG (less than half) compared with conventional control gear (CCG) Dimming Dimmable ECGs make use of the property of a choke whereby its inductance increases as the frequency increases. As the operating frequency is made to increase, the choke connected in series with the lamp supplies a progressively lower current. The frequency is controlled via a 1-10 V or a DALI interface. The dimmable ECGs must also ensure that in the dimmed state the cathodes are constantly heated so that they continue to emit electrons even when the lamp current is at a low level. Lamp life and resistance to switching transients If fluorescent lamps are operated with CCGs and conventional starters their life is shortened considerably as the frequency of on/off switching increases. The same phenomenon can be observed with cold-start ECGs, which have the ability of starting fluorescent lamps instantly. However, the rapid transition from glow discharge temperature to emission temperature seriously damages the cathodes, so frequent switching cycles reduce the life of fluorescent lamps. Warm start control gear behave in a completely different way. In this case, the cathodes are heated before ignition, which virtually eliminates switching damage to the cathodes. The associated delay in ignition, of around a second is not a serious inconvenience. Thermal behaviour The physical properties of fluorescent lamps depend on their ambient temperature. This in turn depends on the characteristic temperature sensitivity of the mercury vapour pressure in the lamp. At low temperatures it is too low so there are too few atoms that can be excited. At excessively high temperatures the high vapour pressure results increasingly in self-absorption of the generated UV radiation. The lamps achieve their maximum luminous output at an ambient temperature of approx. 25°C. In the case of T5 lamps with a tube diameter of 16mm (FH®, FQ®) the rated luminous flux is specified at 25°C, as with other fluorescent lamps but their maximum luminous flux is achieved at an ambient temperature of 33°C to 37°C. In other words, one advantage of T5 lamps is the higher light output from ‘hot’ compact luminaires.
Current-controlled preheating in switch-start mode, preferred in countries with a high mains voltage (200 V or more). Used in most electronic control gear (ECG).
Voltage-controlled preheating with additional transformer for "rapid start" mode.
No preheating (cold start, used for example with slimline lamps). This type of starting reduces the lamp life more than any other type and is therefore not recommended for systems with frequent on/off switching.
Electronic control gear (ECG) converts the mains frequency into a high frequency supply in the region of 35 to 50 kHz. As a result, the 100 Hz flicker that may appear as a stroboscopic effect, for example with rotating machines, is much less noticeable or virtually eliminated. Another advantage of ECG operation is the additional energy savings of around 25% for the same luminous flux, comprising:
10% high luminous efficacy from the fluorescent lamp operating at a high frequency
Much lower losses in the ECG (less than half) compared with conventional control gear (CCG) Dimming Dimmable ECGs make use of the property of a choke whereby its inductance increases as the frequency increases. As the operating frequency is made to increase, the choke connected in series with the lamp supplies a progressively lower current. The frequency is controlled via a 1-10 V or a DALI interface. The dimmable ECGs must also ensure that in the dimmed state the cathodes are constantly heated so that they continue to emit electrons even when the lamp current is at a low level. Lamp life and resistance to switching transients If fluorescent lamps are operated with CCGs and conventional starters their life is shortened considerably as the frequency of on/off switching increases. The same phenomenon can be observed with cold-start ECGs, which have the ability of starting fluorescent lamps instantly. However, the rapid transition from glow discharge temperature to emission temperature seriously damages the cathodes, so frequent switching cycles reduce the life of fluorescent lamps. Warm start control gear behave in a completely different way. In this case, the cathodes are heated before ignition, which virtually eliminates switching damage to the cathodes. The associated delay in ignition, of around a second is not a serious inconvenience. Thermal behaviour The physical properties of fluorescent lamps depend on their ambient temperature. This in turn depends on the characteristic temperature sensitivity of the mercury vapour pressure in the lamp. At low temperatures it is too low so there are too few atoms that can be excited. At excessively high temperatures the high vapour pressure results increasingly in self-absorption of the generated UV radiation. The lamps achieve their maximum luminous output at an ambient temperature of approx. 25°C. In the case of T5 lamps with a tube diameter of 16mm (FH®, FQ®) the rated luminous flux is specified at 25°C, as with other fluorescent lamps but their maximum luminous flux is achieved at an ambient temperature of 33°C to 37°C. In other words, one advantage of T5 lamps is the higher light output from ‘hot’ compact luminaires.
product of illuminance and time
Unit of measurement: lux second [lx s]Exposure H is defined as the product of illuminance and time (at constant illuminance).H = E * t E = illuminance (in lx)t = time (in seconds)Exposure meters are used in photography to determine the ideal exposure time for a given illuminance. Exposure is also an important factor in assessing safe display times for light-sensitive exhibits in museums.
Energy Label
According to EU Directive 92/75/EEC, household lamps operated on main voltage (incandescent lamps and fluorescent lamps with integrated control gear) and household fluorescent lamps (including single and double-ended lamps without integrated control gear) must be marked on their packaging with an energy label indicating their energy efficiency.The light sources are classified in energy efficiency classes A (very efficient) to G (inefficient).
Emergency lighting
There are two types of emergency lighting - standby lighting and safety lighting. Standby lighting takes over the functions of the normal lighting system if the power supply to that system fails so that essential work can continue. In most cases, standby power generators are used and these then supply power to the normal luminaires. The generators must guarantee at least 10% of the illuminance recommended for the activity. There are three types of safety lighting:
Safety lighting for escape routes; safe evacuation calls for a minimum illuminance of >1 lx at a height of 0.2 m, with a uniformity ratio of 1:40.
Escape lighting as minimum background lighting to enable people to reach emergency exits in large rooms.
Safety lighting for hazardous workplaces (near machines with moving parts) if failure of the normal lighting system presents an immediate risk of an accident or injury.
Safety lighting for escape routes; safe evacuation calls for a minimum illuminance of >1 lx at a height of 0.2 m, with a uniformity ratio of 1:40.
Escape lighting as minimum background lighting to enable people to reach emergency exits in large rooms.
Safety lighting for hazardous workplaces (near machines with moving parts) if failure of the normal lighting system presents an immediate risk of an accident or injury.
Monday, May 5, 2008
Dimming lighting system
Dimmable lighting systems were developed originally to meet the need for lighting that was easier on the eye. To an increasing extent, these systems are now also being used for cost saving reasons. Users can control the lighting with remote controls and switches, or control circuits with daylight sensors can be used. Leading edge phase dimming is used for low voltage tungsten halogen lamps operated with magnetic transformers. Trailing edge phase dimming is generally used for those lamps operated with electronic transformers. Compact fluorescent lamps (dimming range 3% to 100%) and fluorescent tubes (dimming range 1% to 100%) with electronic control gear are dimmed via a 1-10 V interface. Cables can either be laid separately (recommended for cable lengths > 100 m) or together, provided the requirements of wiring regulations are met.
Labels:
Ballast,
Fluorescent Lamp,
Incandescent Lamp,
Lighting,
Quality,
Terms
DALI (Digital Adressable Lighting Interface)
DALI is a method of controlling electronic control gear for fluorescent lamps using digital signals. Unlike analogue brightness controls, DALI enables each luminaire to be controlled individually. It can be easily integrated in a building management system. Individual addressing means that not only the luminaires can be controlled but they can provide feedback messages so they can be operated in versatile energy-saving arrangements. DALI supplements Appendix E of the existing IEC Standard 929 in terms of the mode of operation of electronic control gear
1. Digital switching - Luminaires can be switched via the control cables irrespective of polarity.
2. Addressing - 64 ballasts can be addressed, allowing them to be controlled independently with a common control wire.
3. Simple control wiring - Switching and dimming circuits are independent of the wiring layout, allowing maximum flexibility and convenience; this low-voltage wire can be routed in any way and is polarity-free to reduce installation errors.
4. Refurbishment - Control circuits are independent of polarity. This allows the use of existing wiring in old buildings. In new buildings, a five-conductor cable for both power supply and control wiring can be employed.
5. Lighting scenes - Preset lighting scenes for different tasks and moods can be programmed and stored in the DALI ballasts.
6. Flexible room layout - Future layout changes do not necessitate wiring changes.
7. Upgrading - New sensors or interfaces can be added without changing the luminaire wiring; simply choose which luminaires are to be controlled and reprogrammed.
8. Distortion-free - Digital signals allow greater freedom in wiring layout.
9. Flexible - Each sensor can be configured to control any luminaire or group of luminaires.
10. Overlapping groups - Luminaires can be included in more than one sensor group, e.g. movement detection and infrared control.
11. 11 Infrared control zone 1 - Zones can be altered without the need to rewire.
12. Infrared control zone 2
13 PIR (passive infrared) controlled zone
14. Daylight regulating zone - Controlled by Photocell
15. DALI room controller
1. Digital switching - Luminaires can be switched via the control cables irrespective of polarity.
2. Addressing - 64 ballasts can be addressed, allowing them to be controlled independently with a common control wire.
3. Simple control wiring - Switching and dimming circuits are independent of the wiring layout, allowing maximum flexibility and convenience; this low-voltage wire can be routed in any way and is polarity-free to reduce installation errors.
4. Refurbishment - Control circuits are independent of polarity. This allows the use of existing wiring in old buildings. In new buildings, a five-conductor cable for both power supply and control wiring can be employed.
5. Lighting scenes - Preset lighting scenes for different tasks and moods can be programmed and stored in the DALI ballasts.
6. Flexible room layout - Future layout changes do not necessitate wiring changes.
7. Upgrading - New sensors or interfaces can be added without changing the luminaire wiring; simply choose which luminaires are to be controlled and reprogrammed.
8. Distortion-free - Digital signals allow greater freedom in wiring layout.
9. Flexible - Each sensor can be configured to control any luminaire or group of luminaires.
10. Overlapping groups - Luminaires can be included in more than one sensor group, e.g. movement detection and infrared control.
11. 11 Infrared control zone 1 - Zones can be altered without the need to rewire.
12. Infrared control zone 2
13 PIR (passive infrared) controlled zone
14. Daylight regulating zone - Controlled by Photocell
15. DALI room controller
Labels:
Ballast,
basic,
electromagnetic,
Electronic,
Fluorescent Lamp,
Lighting,
Quality,
Terms
Control gear for fluorescent lamps
Discharge lamps have to be operated with control gear to limit the current. There is a choice of conventional, low-loss or electronic control gear. An important factor as far as quality is concerned is their power loss which, together with the lamp wattage, is used to calculate the system wattage.Electronic control gear (ECG) In contrast to conventional control gear, ECGs operate at frequencies at or above 30 kHz which means they offer significant gains in efficiency. These gains are based essentially on two mechanisms:
A reduction in electrode losses.
An increase in luminous efficacy, which is due almost entirely to more efficient conversion of electrical energy into the UV lines of the mercury atom at 185 nm and 254 nm.The use of modern ECGs, above all for fluorescent lamps, has led to significant increases in lighting comfort, economy and reliability.
Lighting comfort
Flicker-free starting
Pleasant flicker-free light with no stroboscopic effects
Silent operation with no annoying hum from chokes
No flashing of faulty lamps
Automatic restart of replacement lamps
Economy
Up to 30% savings in power input compared with CCG operation
More than 50% longer lamp life compared with CCG/LLG thanks to preheat start
Low maintenance costs
Suitable for use in emergency lighting systems to VDE 0108
Reduction in energy costs for air-conditioning systems
Reliability
Safe shutdown of defective lamps
Compliance with the specific standards for safety and EMC
Protective circuit to guard against transient voltage surges and prolonged overvoltages
Dimmable electronic control gear enables compact fluorescent lamps to be dimmed smoothly and without flicker from 100% to 3% luminous flux and tubular fluorescent lamps from 100 % to 1% luminous flux. Control is via a separate 1-10 V interface or a digital addressable lighting interface (DALI).
Conventional control gear (CCG):
This is a simple self-inductance comprising an iron core around which copper wire is wound. Because of its ohmic resistance there is considerable power losses and from self heating. The system wattage for a 26W compact fluorescent lamp operated with conventional control gear is 32 W; in other words, the power loss is 6 W (23%). By contrast, the system wattage with an ECG is 28 W, which corresponds to a power loss of only 7.5%. The various operating modes are as follows:
Switch-start operation
Starter less operation
Control gear with temperature limitation
Switch-start operation can be described as follows:
The voltage needed for the starter to generate a glow discharge between the bimetallic contacts, is lower than the ignition voltage of the lamp with cold cathodes. When mains voltage is applied, the starter generates a glow discharge, the current of which heats up the cathodes. The bimetallic contacts then close and the full short-circuit current of the choke flows through the cathodes of the lamp. As the bimetallic contacts cool down they spring open again. A high voltage pulse is generated by the choke to ignite the lamp. Once the lamp has ignited only the lamp voltage is across the starter. This voltage is too low to cause the starter to initiate a glow discharge, so does not attempt to light the lamp.Special lamps are needed for starter-less operation. Whereas fluorescent lamps connected to a European 230-240 V mains can be operated with simple chokes and an additional preheating transformer or a sophisticated double resonance choke is needed for starter-less operation. The voltage for lamps connected to American 120 V supply systems has to be transformed with two additional heater windings on the control transformer, which involves little extra outlay. For this reason, starter-less circuits are widespread in the USA. Control gear with temperature limitation help ensure that dangerous overheating does not occur as lamps reach the end of their lives. This protection is provided by thermal cut-outs approved in VDE 0712 T10 The European Ballast Directive (2000/55/EC) has classified all fluorescent ballasts in terms of their energy efficiency. The most inefficient types will be legally banned from sale in Europe from May 2002. The aim of the Directive is to encourage the widespread use of electronic control gear which are the best in terms of energy efficiency. Low-loss gear (LLG): Compared to conventional control gear, low-loss gear has a lower power loss but are larger and are more costly to manufacture because of their improved design and larger iron cores. The system wattage for a 26 W compact fluorescent lamp, for example, is around 30 W
A reduction in electrode losses.
An increase in luminous efficacy, which is due almost entirely to more efficient conversion of electrical energy into the UV lines of the mercury atom at 185 nm and 254 nm.The use of modern ECGs, above all for fluorescent lamps, has led to significant increases in lighting comfort, economy and reliability.
Lighting comfort
Flicker-free starting
Pleasant flicker-free light with no stroboscopic effects
Silent operation with no annoying hum from chokes
No flashing of faulty lamps
Automatic restart of replacement lamps
Economy
Up to 30% savings in power input compared with CCG operation
More than 50% longer lamp life compared with CCG/LLG thanks to preheat start
Low maintenance costs
Suitable for use in emergency lighting systems to VDE 0108
Reduction in energy costs for air-conditioning systems
Reliability
Safe shutdown of defective lamps
Compliance with the specific standards for safety and EMC
Protective circuit to guard against transient voltage surges and prolonged overvoltages
Dimmable electronic control gear enables compact fluorescent lamps to be dimmed smoothly and without flicker from 100% to 3% luminous flux and tubular fluorescent lamps from 100 % to 1% luminous flux. Control is via a separate 1-10 V interface or a digital addressable lighting interface (DALI).
Conventional control gear (CCG):
This is a simple self-inductance comprising an iron core around which copper wire is wound. Because of its ohmic resistance there is considerable power losses and from self heating. The system wattage for a 26W compact fluorescent lamp operated with conventional control gear is 32 W; in other words, the power loss is 6 W (23%). By contrast, the system wattage with an ECG is 28 W, which corresponds to a power loss of only 7.5%. The various operating modes are as follows:
Switch-start operation
Starter less operation
Control gear with temperature limitation
Switch-start operation can be described as follows:
The voltage needed for the starter to generate a glow discharge between the bimetallic contacts, is lower than the ignition voltage of the lamp with cold cathodes. When mains voltage is applied, the starter generates a glow discharge, the current of which heats up the cathodes. The bimetallic contacts then close and the full short-circuit current of the choke flows through the cathodes of the lamp. As the bimetallic contacts cool down they spring open again. A high voltage pulse is generated by the choke to ignite the lamp. Once the lamp has ignited only the lamp voltage is across the starter. This voltage is too low to cause the starter to initiate a glow discharge, so does not attempt to light the lamp.Special lamps are needed for starter-less operation. Whereas fluorescent lamps connected to a European 230-240 V mains can be operated with simple chokes and an additional preheating transformer or a sophisticated double resonance choke is needed for starter-less operation. The voltage for lamps connected to American 120 V supply systems has to be transformed with two additional heater windings on the control transformer, which involves little extra outlay. For this reason, starter-less circuits are widespread in the USA. Control gear with temperature limitation help ensure that dangerous overheating does not occur as lamps reach the end of their lives. This protection is provided by thermal cut-outs approved in VDE 0712 T10 The European Ballast Directive (2000/55/EC) has classified all fluorescent ballasts in terms of their energy efficiency. The most inefficient types will be legally banned from sale in Europe from May 2002. The aim of the Directive is to encourage the widespread use of electronic control gear which are the best in terms of energy efficiency. Low-loss gear (LLG): Compared to conventional control gear, low-loss gear has a lower power loss but are larger and are more costly to manufacture because of their improved design and larger iron cores. The system wattage for a 26 W compact fluorescent lamp, for example, is around 30 W
Labels:
Fluorescent Lamp,
Incandescent Lamp,
Lamp Holders,
Lighting,
Quality,
Terms
Constant light control
This is incorporated into dimmable lighting installations with the aim of reducing lighting costs, increasing lighting comfort and promoting individuality.This form of control is based on a dimmable ECG with a 1-10 V interface or DALI in combination with appropriate sensors. A distinction is made between automatic controllers, manual controllers and complex controllers. The choice of appropriate 1-10V dimmer components depends to a large extent on the application.The lighting system is controlled by light sensors according to the amount of available daylight, so full use is made of free natural sunlight. Energy savings of up to 60% are possible, rising to 70% if motion detectors, time switches and sensors with automatic disconnection circuits are used.
Labels:
basic,
Fluorescent Lamp,
Incandescent Lamp,
Lighting,
Quality,
Terms
Computer workstations
Guidelines for lighting at computer workstations are given in DIN 5035, Part 2 and EU Directive 90/270/EWG. Its appendix contains the following minimum requirements:Lighting
General lighting and/or special lighting (task lamps) must be dimensioned and arranged so that lighting conditions are satisfactory and contrast between the screen and its surroundings is adequate, according to the type of activity and the viewing requirements of the user.
Glare, reflex or reflections on the screen or any reflective surface must be avoided by arranging the objects in the work area according to the arrangement and technical properties of the artificial light sources. Reflex and glare
Computer workstations must be set up so that light sources such as windows, other openings, transparent or translucent partitions, bright items of furniture and light coloured walls do not produce reflections on the screen.
Windows have to be equipped with suitable adjustable mechanisms for preventing or reducing the amount of daylight falling on the workplace. For further technical information see the DIN 5035-7 and DIN 66234-7 standards.
General lighting and/or special lighting (task lamps) must be dimensioned and arranged so that lighting conditions are satisfactory and contrast between the screen and its surroundings is adequate, according to the type of activity and the viewing requirements of the user.
Glare, reflex or reflections on the screen or any reflective surface must be avoided by arranging the objects in the work area according to the arrangement and technical properties of the artificial light sources. Reflex and glare
Computer workstations must be set up so that light sources such as windows, other openings, transparent or translucent partitions, bright items of furniture and light coloured walls do not produce reflections on the screen.
Windows have to be equipped with suitable adjustable mechanisms for preventing or reducing the amount of daylight falling on the workplace. For further technical information see the DIN 5035-7 and DIN 66234-7 standards.
Colour rendering
Depending on the location and the purpose, artificial light should enable colours to be perceived correctly as though being seen by natural daylight. Such assessments are based on the colour rendering properties of a light source, which are expressed in terms of the "general colour rendering index" Ra. The colour rendering index is a measure of the comparison between the chromaticity of an object under the light source being measured and its chromaticity under a reference light source.
Colour rendering property
Colour rendering group
Colour rendering index Ra
Typical lamp
Excellent
1 A
90
Tungsten halogen lamps, LUMILUX DE LUXE fluorescent lampsHQI.../D
Very good
1 B
80 - 89
LUMILUX fluorescent lamps HQI.../NDL or WDL
Good
2 A
70 - 79
Basic fluorescent lamps (25)
Satisfactory
2 B
60 - 69
Basic fluorescent lamps (20,23,30)
Fair
3
40 - 59
HQL
Poor
4
39
High-pressure and low-pressure sodium discharge lamps
The chromaticity of eight (or 14) test colours standardized in DIN 6169 that occur when they are illuminated by the light source being tested are compared with the same test colour when illuminated by the reference light source. The smaller the difference the better the colour rendering property of the lamp being tested. A light source with an Ra value of 100 shows all the colours perfectly, as in the case of the reference light source. The lower the Ra value, the worse the colour rendering.
Test colours for Ra8
R1
Old rose
R5
Turquoise
R2
Mustard yellow
R6
Sky blue
R3
Yellow-green
R7
Violet
R4
Light green
R8
Lilac
Additional test colours with saturated colours (Ra14)
R9
Red
R12
Blue
R10
Yellow
R13
Skin tone
R11
Green
R14
Leaf green
Colour rendering property
Colour rendering group
Colour rendering index Ra
Typical lamp
Excellent
1 A
90
Tungsten halogen lamps, LUMILUX DE LUXE fluorescent lampsHQI.../D
Very good
1 B
80 - 89
LUMILUX fluorescent lamps HQI.../NDL or WDL
Good
2 A
70 - 79
Basic fluorescent lamps (25)
Satisfactory
2 B
60 - 69
Basic fluorescent lamps (20,23,30)
Fair
3
40 - 59
HQL
Poor
4
39
High-pressure and low-pressure sodium discharge lamps
The chromaticity of eight (or 14) test colours standardized in DIN 6169 that occur when they are illuminated by the light source being tested are compared with the same test colour when illuminated by the reference light source. The smaller the difference the better the colour rendering property of the lamp being tested. A light source with an Ra value of 100 shows all the colours perfectly, as in the case of the reference light source. The lower the Ra value, the worse the colour rendering.
Test colours for Ra8
R1
Old rose
R5
Turquoise
R2
Mustard yellow
R6
Sky blue
R3
Yellow-green
R7
Violet
R4
Light green
R8
Lilac
Additional test colours with saturated colours (Ra14)
R9
Red
R12
Blue
R10
Yellow
R13
Skin tone
R11
Green
R14
Leaf green
Characteristics of materials
When light hits material, such as a window pane, there are three different phenomena that come into play. Some of the light is reflected, some is absorbed by the material and the rest is transmitted. The resultant luminous flux components are known as Fr (reflected luminous flux), Fa (absorbed luminous flux) and Ft (transmitted luminous flux).The quantitative relationship between these parameters is as follows:
degree of reflectance r= Fr / F
degree of absorption a= Fa / F
degree of transmittance t= Ft / F (where r a t = 1 and Fr Fa Ft = F)
The luminous flux absorbed by material is converted into heat, which increases its temperature. The darker the material, the more luminous flux is absorbed. A single glass sheet with a thickness of 4 mm, for example, reflects 8% of the luminous flux that falls on it, 90% is transmitted and 2% is absorbed.The diagram below shows the extreme forms, namely fully directed and fully dispersed reflectance and transmittance.

Reflectance and transmittance
degree of reflectance r= Fr / F
degree of absorption a= Fa / F
degree of transmittance t= Ft / F (where r a t = 1 and Fr Fa Ft = F)
The luminous flux absorbed by material is converted into heat, which increases its temperature. The darker the material, the more luminous flux is absorbed. A single glass sheet with a thickness of 4 mm, for example, reflects 8% of the luminous flux that falls on it, 90% is transmitted and 2% is absorbed.The diagram below shows the extreme forms, namely fully directed and fully dispersed reflectance and transmittance.
Reflectance and transmittance
Luminance L
Unit of measurement: candela per square metre [cd/m2]1 [cd/m2] = 0,0001 cd/cm2 Luminance L is measured brightness of a light source or an illuminated surface. The eye is very good at distinguishing between different luminance values:
Light source
Average luminance [cd/m2]
Light source
Average luminance [cd/m2]
Xenon short-arc lamp
200 000 - 5000 000 000
Candle
7 500
Sun
1 600 000 000
Blue sky
5 000
Metal halide lamp
10 000 000 - 60 000 000
Specular louvred luminaire
100
Incandescent lamp
2 000 000 -26 000 000
Preferred values for indoor lighting
50 - 500
Compact fluorescent lamp
20 000 -70 000
White paper at 500 lx
100
Fluorescent lamp
5 000 - 30 000
White paper at 5 lx
1
Sunlit clouds
10 000
Light source
Average luminance [cd/m2]
Light source
Average luminance [cd/m2]
Xenon short-arc lamp
200 000 - 5000 000 000
Candle
7 500
Sun
1 600 000 000
Blue sky
5 000
Metal halide lamp
10 000 000 - 60 000 000
Specular louvred luminaire
100
Incandescent lamp
2 000 000 -26 000 000
Preferred values for indoor lighting
50 - 500
Compact fluorescent lamp
20 000 -70 000
White paper at 500 lx
100
Fluorescent lamp
5 000 - 30 000
White paper at 5 lx
1
Sunlit clouds
10 000
Luminous intensity I
Amount of light Q Unit of measurement: kilolumens per hour [klm/h].The amount of light is the luminous flux emitted by a light source over time.
Luminous intensity I
Unit of measurement: candela [cd].A light source generally emits its luminous flux F in different directions. Luminous intensity is the luminous flux emitted through unit solid angle (1 Steradian) in a particular direction.

The spatial distribution of the luminous intensity of a light source produces a three-dimensional luminous intensity distribution graph. A section through this graph produces the luminous intensity distribution curve for the relevant plane. It is usual to use the polar coordinates or the Cartesian coordinates and normalize the values to a luminous flux of 1000 lm for luminaires so the figures can be more easily compared.
Luminous intensity I
Unit of measurement: candela [cd].A light source generally emits its luminous flux F in different directions. Luminous intensity is the luminous flux emitted through unit solid angle (1 Steradian) in a particular direction.
The spatial distribution of the luminous intensity of a light source produces a three-dimensional luminous intensity distribution graph. A section through this graph produces the luminous intensity distribution curve for the relevant plane. It is usual to use the polar coordinates or the Cartesian coordinates and normalize the values to a luminous flux of 1000 lm for luminaires so the figures can be more easily compared.
Adaptation of Light
This is the ability of the eye to adjust to changes in luminance by making the pupil larger or smaller. It means we can see correctly across a wide range of illuminance values. The time taken to adapt in this way is largely determined by the luminances at the start and end of the adaptation process. This adaptation takes place very quickly from dark to light (brightness adaptation) but much more slowly (30 minutes or more) from light to dark (darkness adaptation).
Labels:
basic,
Fluorescent Lamp,
Incandescent Lamp,
Lighting,
Quality,
Terms
Subscribe to:
Posts (Atom)