Wednesday, May 14, 2008

what is Illuminance E ?

The unit of measurement is the lux [lx]: E = F / A F = luminous flux in lumenensA = area illuminated in m2 Illuminance E is the ratio between the luminous flux and the area to be illuminated. An illuminance of 1 lx occurs when a luminous flux of 1 lm falls evenly on an area of 1 m². Based on the definitions for illuminance luminous intensity and solid angle W = A/r2, we obtain the following formula for illuminance: E = I / r2Photometric inverse square law r = distance of the light source to the object in mA = area illuminated in m2I = luminous intensity in Candela It is assumed that the light falls perpendicular to the surface it illuminates. If the surface is at an angle a then E = I/r2 must be multiplied by cos a.

what is Halogen cycle

Halogen cycle The main characteristics of an incandescent lamp, namely its luminous efficacy and service life, are determined to a large extent by the filament temperature. The higher the filament temperature, the higher the luminous efficacy but the shorter the life of the lamp. This reduction in the life of the lamp is a consequence of the rate at which tungsten evaporates from the filament. This rate increases rapidly with increasing temperature. Not only does it blacken the inside of the bulb, it causes the filament ultimately to burn out. This blackening of the bulb can be effectively countered by adding halogens to the filler gas to prevent evaporated tungsten from depositing on the bulb wall by a "halogen cycle process". The tungsten that evaporates from the filament during normal operation migrates towards the bulb wall by diffusion or thermal convection In the temperature region <1400>1400 K) where they dissociate back to tungsten and halogen, leaving the halogen to repeat the cycle. Some of the tungsten is transported back to the filament, but not to its original location. The "normal halogen cycle" therefore merely prevents the bulb from blackening, it does not extend the life of the lamp. The lamp comes to the end of its life when the filament melts at one of its hot spots.

Friday, May 9, 2008

Pulse ignition systems

For HS, HI and C-HI lamps - PZ 1000 K / PZ 1000 K P20 For high-pressure sodium lamps (HS), metal halide lamps (HI) 35 -1000 W and ceramic discharge tube lamps (C-HI) 35 - 400 W Ignition voltage: 1.8 - 2.3 kV or 4.0 - 5.0 kV, respectively No. of pulses: 2 per mains period Load capacitance: 20 -1000 pF Suitable ballast types: NaHJ ... PZ/PZT with special winding tapping point, whose position is determined by the magnitude of the ignition voltage


For HI lamps - PZI 1000/1 K and PZI 2000/400 V 1.2 kV For metal halide lamps (HI) with an ignition voltage up to 0.9 kV or 1.3 kV, respectively. No. of pulses: 1per mains period Load capacitance: max. 10,000 pF Suitable ballast models: Q...


Circuit diagrams for high-pressure sodium lamps and metal halide lamps

Circuits for Discharge Lamps
Superimposed ignition of HS and HI lamps

Circuits for Discharge Lamps
Pulse ignition of HS and HI lamps


Circuits for Discharge Lamps
Power reduction of HM lamps

Circuits for Discharge Lamps

NHT-SDX lamps 100 V/200 V (autotransformer for European voltage)

Components for discharge lamps

If the electrical current through a discharge lamp is increased, a discharge channel with very high luminous efficiency is created in the discharge chamber; luminous flux and light output increase substantially. The internal pressure of the discharge chamber rises and attains between 1and 10 bar these are so-called high-pressure discharge lamps (general: discharge lamp). The light output and colour rendition of high-pressure lamps vary considerably depending on the lamp family.
Discharge lamps can only be operated with ballasts. Ignitors are additionally required for sodium lamps and metal halide lamps. Furthermore, to compensate blind current when using magnetic ballasts, compensation capacitors must be fitted. The lampholders enable the lamp to be fixed in the luminaire and ensure simple exchange of lamps at the end of their service life. As well as stabilising the lamp´s operating point, ballasts also influence the lamp´s output and luminous flux, the system´s light output, the service life of the lamps as well as the colour temperature of the light

High-pressure sodium lamps (HS lamps)
Metal halide lamps (HI lamps)
Metal halide lamps with a ceramic discharge tube (C-HI lamps)
Mercury vapour lamps (HM lamps)
Low-pressure sodium lamps (LS lamps)
Ballasts can be of either electromagnetic or electronic construction. Unlike with fluorescent lamps, lamp efficiency is not decisively altered by the use of electronic ballasts. In contrast, electronic ballasts lead to a reduction of the inherent losses and thus to an increase in system efficiency. In addition, electronic ballasts ensure gentle lamp operation, which increases the lamp´s service life.

Thursday, May 8, 2008

product of illuminance and time

Unit of measurement: lux second [lx s]Exposure H is defined as the product of illuminance and time (at constant illuminance).H = E * t E = illuminance (in lx)t = time (in seconds)Exposure meters are used in photography to determine the ideal exposure time for a given illuminance. Exposure is also an important factor in assessing safe display times for light-sensitive exhibits in museums.

Monday, May 5, 2008

Dimming lighting system

Dimmable lighting systems were developed originally to meet the need for lighting that was easier on the eye. To an increasing extent, these systems are now also being used for cost saving reasons. Users can control the lighting with remote controls and switches, or control circuits with daylight sensors can be used. Leading edge phase dimming is used for low voltage tungsten halogen lamps operated with magnetic transformers. Trailing edge phase dimming is generally used for those lamps operated with electronic transformers. Compact fluorescent lamps (dimming range 3% to 100%) and fluorescent tubes (dimming range 1% to 100%) with electronic control gear are dimmed via a 1-10 V interface. Cables can either be laid separately (recommended for cable lengths > 100 m) or together, provided the requirements of wiring regulations are met.

DALI (Digital Adressable Lighting Interface)

DALI is a method of controlling electronic control gear for fluorescent lamps using digital signals. Unlike analogue brightness controls, DALI enables each luminaire to be controlled individually. It can be easily integrated in a building management system. Individual addressing means that not only the luminaires can be controlled but they can provide feedback messages so they can be operated in versatile energy-saving arrangements. DALI supplements Appendix E of the existing IEC Standard 929 in terms of the mode of operation of electronic control gear
1. Digital switching - Luminaires can be switched via the control cables irrespective of polarity.
2. Addressing - 64 ballasts can be addressed, allowing them to be controlled independently with a common control wire.
3. Simple control wiring - Switching and dimming circuits are independent of the wiring layout, allowing maximum flexibility and convenience; this low-voltage wire can be routed in any way and is polarity-free to reduce installation errors.
4. Refurbishment - Control circuits are independent of polarity. This allows the use of existing wiring in old buildings. In new buildings, a five-conductor cable for both power supply and control wiring can be employed.
5. Lighting scenes - Preset lighting scenes for different tasks and moods can be programmed and stored in the DALI ballasts.
6. Flexible room layout - Future layout changes do not necessitate wiring changes.
7. Upgrading - New sensors or interfaces can be added without changing the luminaire wiring; simply choose which luminaires are to be controlled and reprogrammed.
8. Distortion-free - Digital signals allow greater freedom in wiring layout.
9. Flexible - Each sensor can be configured to control any luminaire or group of luminaires.
10. Overlapping groups - Luminaires can be included in more than one sensor group, e.g. movement detection and infrared control.
11. 11 Infrared control zone 1 - Zones can be altered without the need to rewire.
12. Infrared control zone 2
13 PIR (passive infrared) controlled zone
14. Daylight regulating zone - Controlled by Photocell
15. DALI room controller

Control gear for fluorescent lamps

Discharge lamps have to be operated with control gear to limit the current. There is a choice of conventional, low-loss or electronic control gear. An important factor as far as quality is concerned is their power loss which, together with the lamp wattage, is used to calculate the system wattage.Electronic control gear (ECG) In contrast to conventional control gear, ECGs operate at frequencies at or above 30 kHz which means they offer significant gains in efficiency. These gains are based essentially on two mechanisms:
A reduction in electrode losses.
An increase in luminous efficacy, which is due almost entirely to more efficient conversion of electrical energy into the UV lines of the mercury atom at 185 nm and 254 nm.The use of modern ECGs, above all for fluorescent lamps, has led to significant increases in lighting comfort, economy and reliability.
Lighting comfort
Flicker-free starting
Pleasant flicker-free light with no stroboscopic effects
Silent operation with no annoying hum from chokes
No flashing of faulty lamps
Automatic restart of replacement lamps
Economy
Up to 30% savings in power input compared with CCG operation
More than 50% longer lamp life compared with CCG/LLG thanks to preheat start
Low maintenance costs
Suitable for use in emergency lighting systems to VDE 0108
Reduction in energy costs for air-conditioning systems
Reliability
Safe shutdown of defective lamps
Compliance with the specific standards for safety and EMC
Protective circuit to guard against transient voltage surges and prolonged overvoltages
Dimmable electronic control gear enables compact fluorescent lamps to be dimmed smoothly and without flicker from 100% to 3% luminous flux and tubular fluorescent lamps from 100 % to 1% luminous flux. Control is via a separate 1-10 V interface or a digital addressable lighting interface (DALI).
Conventional control gear (CCG):
This is a simple self-inductance comprising an iron core around which copper wire is wound. Because of its ohmic resistance there is considerable power losses and from self heating. The system wattage for a 26W compact fluorescent lamp operated with conventional control gear is 32 W; in other words, the power loss is 6 W (23%). By contrast, the system wattage with an ECG is 28 W, which corresponds to a power loss of only 7.5%. The various operating modes are as follows:
Switch-start operation
Starter less operation
Control gear with temperature limitation
Switch-start operation can be described as follows:
The voltage needed for the starter to generate a glow discharge between the bimetallic contacts, is lower than the ignition voltage of the lamp with cold cathodes. When mains voltage is applied, the starter generates a glow discharge, the current of which heats up the cathodes. The bimetallic contacts then close and the full short-circuit current of the choke flows through the cathodes of the lamp. As the bimetallic contacts cool down they spring open again. A high voltage pulse is generated by the choke to ignite the lamp. Once the lamp has ignited only the lamp voltage is across the starter. This voltage is too low to cause the starter to initiate a glow discharge, so does not attempt to light the lamp.Special lamps are needed for starter-less operation. Whereas fluorescent lamps connected to a European 230-240 V mains can be operated with simple chokes and an additional preheating transformer or a sophisticated double resonance choke is needed for starter-less operation. The voltage for lamps connected to American 120 V supply systems has to be transformed with two additional heater windings on the control transformer, which involves little extra outlay. For this reason, starter-less circuits are widespread in the USA. Control gear with temperature limitation help ensure that dangerous overheating does not occur as lamps reach the end of their lives. This protection is provided by thermal cut-outs approved in VDE 0712 T10 The European Ballast Directive (2000/55/EC) has classified all fluorescent ballasts in terms of their energy efficiency. The most inefficient types will be legally banned from sale in Europe from May 2002. The aim of the Directive is to encourage the widespread use of electronic control gear which are the best in terms of energy efficiency. Low-loss gear (LLG): Compared to conventional control gear, low-loss gear has a lower power loss but are larger and are more costly to manufacture because of their improved design and larger iron cores. The system wattage for a 26 W compact fluorescent lamp, for example, is around 30 W

Constant light control

This is incorporated into dimmable lighting installations with the aim of reducing lighting costs, increasing lighting comfort and promoting individuality.This form of control is based on a dimmable ECG with a 1-10 V interface or DALI in combination with appropriate sensors. A distinction is made between automatic controllers, manual controllers and complex controllers. The choice of appropriate 1-10V dimmer components depends to a large extent on the application.The lighting system is controlled by light sensors according to the amount of available daylight, so full use is made of free natural sunlight. Energy savings of up to 60% are possible, rising to 70% if motion detectors, time switches and sensors with automatic disconnection circuits are used.

Colour rendering

Depending on the location and the purpose, artificial light should enable colours to be perceived correctly as though being seen by natural daylight. Such assessments are based on the colour rendering properties of a light source, which are expressed in terms of the "general colour rendering index" Ra. The colour rendering index is a measure of the comparison between the chromaticity of an object under the light source being measured and its chromaticity under a reference light source.


Colour rendering property
Colour rendering group
Colour rendering index Ra
Typical lamp
Excellent
1 A
90
Tungsten halogen lamps, LUMILUX DE LUXE fluorescent lampsHQI.../D
Very good
1 B
80 - 89
LUMILUX fluorescent lamps HQI.../NDL or WDL
Good
2 A
70 - 79
Basic fluorescent lamps (25)
Satisfactory
2 B
60 - 69
Basic fluorescent lamps (20,23,30)
Fair
3
40 - 59
HQL
Poor
4
39
High-pressure and low-pressure sodium discharge lamps
The chromaticity of eight (or 14) test colours standardized in DIN 6169 that occur when they are illuminated by the light source being tested are compared with the same test colour when illuminated by the reference light source. The smaller the difference the better the colour rendering property of the lamp being tested. A light source with an Ra value of 100 shows all the colours perfectly, as in the case of the reference light source. The lower the Ra value, the worse the colour rendering.

Test colours for Ra8
R1
Old rose

R5
Turquoise

R2
Mustard yellow

R6
Sky blue

R3
Yellow-green

R7
Violet

R4
Light green

R8
Lilac

Additional test colours with saturated colours (Ra14)
R9
Red

R12
Blue

R10
Yellow

R13
Skin tone

R11
Green

R14
Leaf green

Burning position

The burning position defines the position in which lamps may or may not be operated. A combination of a letter and a number is used in which the letter indicates the datum alignment and the number is the half-angle of the recommended range. There are three basic datum positions: h = vertical, base ups = vertical, base downp = horizontal

Schematic diagram for burning positions

Luminance L

Unit of measurement: candela per square metre [cd/m2]1 [cd/m2] = 0,0001 cd/cm2 Luminance L is measured brightness of a light source or an illuminated surface. The eye is very good at distinguishing between different luminance values:

Light source
Average luminance [cd/m2]
Light source
Average luminance [cd/m2]
Xenon short-arc lamp
200 000 - 5000 000 000
Candle
7 500
Sun
1 600 000 000
Blue sky
5 000
Metal halide lamp
10 000 000 - 60 000 000
Specular louvred luminaire
100
Incandescent lamp
2 000 000 -26 000 000
Preferred values for indoor lighting
50 - 500
Compact fluorescent lamp
20 000 -70 000
White paper at 500 lx
100
Fluorescent lamp
5 000 - 30 000
White paper at 5 lx
1
Sunlit clouds
10 000

Adaptation of Light

This is the ability of the eye to adjust to changes in luminance by making the pupil larger or smaller. It means we can see correctly across a wide range of illuminance values. The time taken to adapt in this way is largely determined by the luminances at the start and end of the adaptation process. This adaptation takes place very quickly from dark to light (brightness adaptation) but much more slowly (30 minutes or more) from light to dark (darkness adaptation).

Absorption

This is property of material to convert the radiation they receive (such as light) into different forms of energy, mostly heat. A measure of this property is the degree of absorption a = Fa / F, the ratio of the luminous flux absorbed to the incident luminous flux. (Reflection, Transmittance). a = Fa / F F = incident luminous fluxFa = absorbed luminous fluxFr = reflected luminous fluxFt = transmitted luminous flux


Reflection, Absorption and Transmission in schematic format

lamp designations

TC-S
Tube Compact-Single
TC-SEL
Tube Compact-Single Electronic
TC-D
Tube Compact-Double
TC-DEL
Tube Compact-Double Electronic
TC-T
Tube Compact-Triple
TC-TEL
Tube Compact-Triple Electronic
TC-Q
Tube Compact-Quad
TC-QEL
Tube Compact-Quad Electronic
TC-DD
Tube Compact-Double D-Shape
TC-L
Tube Compact-Long
TC-F
Tube Compact-Flat
T2 (T7)
Tube Ø 2/8" (7 mm)
T5 (T16)
Tube Ø 5/8" (16 mm)
T8 (T26)
Tube Ø 8/8" (26 mm)
T12 (T38)
Tube Ø 12/8" (38 mm)
T-U
Tube U-Shape
T-R
Tube Ring-Shape
T-R5 (T-R16)
Tube Ring-Shape Ø 5/8" (16 mm)

Explanation of the IP numbers

Explanation of the IP numbers for the degree of protection in accordance with DIN IEC 598/VDE 0711
Number
1st number

Brief description
Brief explanation of which foreign bodies must not be allowed to penetrate into the casing
2nd number

Brief description
Details on the protection to be provided by the casing
IP20
1st number
2
Protected from solid foreign bodies
Fingers and the like up to 80 mm long. Foreign bodies greater than 12 mm dia.
2nd number
0
Unprotected
No special protection.
IP...1
2nd number
1
Protected from water droplets
Water droplets (droplets falling vertically) do not cause any damage.
IP...3
2nd number
3
Protected from water splashes
Water spray from an angle of up to 60° from the vertical must not cause any damage.
IP...4
2nd number
4
Protected from water splashes
Water splashes from any direction must not cause any damage.
IP...5
2nd number
5
Protected from water jets
Water jets from any direction must not cause any damage.
IP...7
2nd number
7
Watertight (immersible)
No water in dangerous quantities may penetrate when immersed in water in the given conditions in terms of pressure and time.
IP...8
2nd number
8
Tight to pressurized water (under water)
The equipment is suitable for continuous operation under water in the conditions stated by the manufacturer.
IP4...
1st number
4
Protection from foreign bodies greater than 1 mm
Wires or strips thicker than 1 mm. Foreign bodies greater than 1 mm dia.
IP5...
1st number
5
Dust-protected
Dust penetration is not completely prevented but dust does not penetrate in quantities which inhibit proper operation.
IP6...
1st number
6
Dust-tight
No dust penetration.

Sunday, May 4, 2008

Lampholders for compact fluorescent lamps




Vossloh-Schwabe produces the majority of lampholders for TC lamps using PBT, a thermoplastic material. This highly heat-resistant material is responsible for the T140 temperature rating. Leading lamp manufacturers also use PBT for the lamp bases they produce. This material harmonisation in conjunction with fatigue-free, stainless steel lamp mounting springs ensures a permanently secure lamp fit.
Lampholders for double-ended fluorescent lamps
VS lampholders for T lamps are characterised by a number of technical features that guarantee a high degree of reliability and safety. In the first instance, the large rotor, which is characteristic of the vast majority of these lampholders, acts as a heat shield. Made of extremely heat-resistant PBT, the rotor´s fatigue strength at elevated temperatures amounts to 140 °C. Thus shielded against the heat of the lamp base, these lampholders attract a temperature rating of T130. In addition, Vossloh-Schwabe produces another series of rotor-like push-through lampholders whose complete front plate is made of PBT and thus acts as a heat shield. These lampholders attract a temperature rating of T140.
The maximum permissible temperature at the lampholder rear of Tm 110 °C is applicable to all lampholder types. The second key feature of these lampholders is a highly effective lamp pin support that reliably prevents base pin deflection even on older lamps and guarantees a durable and firm contact.




Push-through lampholders
Push-through lampholders are inserted from below through a cut-out in the luminaire casing and are secured by lateral catches. This type of lampholder is frequently used in luminaires on which the lampholder remains visible from the outside, e.g. in so-called strip lighting. The electrical leads are laid beneath the sheet metal level. With push-through lampholders, the starter essentially determines the dimensions of the luminaire because it has to remain accessible from the outside and is thus positioned vertically in front of the lampholder.


Push-fit lampholders
This lampholder type, which is frequently found in surface-mounted ceiling and built-in luminaires, is pushed into the luminaire casing from above. The lampholder foot should protrude by no more than 4 mm to match the usual height of the spacing cams in the luminaire casing. These lampholders are mostly wired above the luminaire casing to the side of the lampholder. However, there are also lampholders on which the wiring runs through the lampholder foot, with the leads laid beneath the luminaire casing.







Built-in lampholders
This design is also predominantly used for recessed ceiling and surface-mounted luminaires. However, unlike push-fit lampholders, built-in lampholders are usually fitted at the ends of the luminaire boxes. In addition to the usual fixing with split pins attached to the rear, there are also countless versions with fixing clips, push-fit studs or screw-in holes, which are also available with spring-loaded length compensation. Built-in lampholders offer luminaire designers a wealth of scope regarding the choice of lamp position in relation to the reflector. This enables great variation in light distribution as the lampholder does not dictate the distance of the centre of the lamp from the metal casing.


Surface-mounting lampholders
The fastening system of surface-mounting lampholders usually consists of screws or rivets above a fixing level, along which the wiring is also laid. As this type of installation is usually too costly nowadays for large unit numbers, these lampholders are used almost exclusively for special applications, e.g. displays or illuminated advertisements.

Connecting terminals

In the interest of ensuring firm contacts and long component service life, Vossloh-Schwabe uses only top-quality materials for plastic or metal parts during the production of connection terminals. These quality features apply to both Vossloh-Schwabe´s luminaire connection terminals as well as to the terminals fitted to ballasts and lampholders.
Notes on connection terminals on electronic ballasts
Vossloh-Schwabe electronic ballasts are fitted with installation-friendly push-in connectors. In addition, many models for linear fluorescent lamps are also available with IDC terminals (for solid conductors, 0.5 mm²) and supplementary push-in terminals (for solid conductors, 0.5 -1.5 mm², stripped length 8+1mm or 7.5 - 8.5 mm). IDC terminals permit automated luminaire wiring and testing using the ALF system and are thus particularly efficient.
Notes on connection terminals on electromagnetic ballasts
Standard issue Vossloh-Schwabe electromagnetic ballasts are fitted with installation-friendly IDC/push-in terminals (combination terminals) or push-in terminals. The terminals are designed for use with solid conductors with cross-sections of 0.5 -1.0 mm² (combination terminals) or up to 1.5 mm² (push-in terminals) and are approved for current loads of up to 3 A (combination terminal) and 16 A (push-in terminal). The lead stripping length totals 8±1mm for push-in terminals; leads must not be stripped for IDC terminals.
On request, many ballasts can also be provided with screw terminals (current load up to 16 A) for conductor cross-sections of 0.5 to 2.5 mm².
Notes on connection terminals on lampholders
Vossloh-Schwabe usually equips lampholders for T and TC lamps as well as starter lampholders with installation-friendly push-in terminals for solid conductors of 0.5 -1.0 mm². Most lampholders are fitted with twin push-in terminals and thus permit through-wiring. The required lead stripping length amounts to 8+1mm for all types.





IDC terminals
In order to fully exploit the vast potential for rationalisation offered by automated wiring and testing with the ALF system, a totally new component family was developed that is equipped with the VDE-tested IDC terminal technology. This technology has already been used very successfully on a large scale in other branches of industry. This modification of the terminal geometry dispenses with the stripping of conductors that is required for the push-in, screw or crimping methods. This triedand-tested IDC terminal technology has created the foundation for efficient automation as it ensures high connection quality, rapid contacting as well as quality assurance. Components equipped in this fashion make it possible to through-wire several terminals with a single conductor. This constitutes a further economic advantage as it significantly reduces the required conductor lengths. Furthermore, this design principle makes it possible to use adapters to simply and reliably make electrical contact from above for a VDE-compatible final luminaire inspection.

Electronic ballasts (EB)

Ballasts for fluorescent lamps
The operation of a fluorescent lamp depends on a ballast that stabilises the lamp´s preheat current after connection to the mains and, in conjunction with the starter, also supplies the required lamp ignition voltage after preheating. After lamp ignition, the ballast then serves to limit the lamp current. As fluorescent lamps are characterised by a negative characteristic current-voltage curve, lamp current stabilisation is extremely important with regard to both the lamp´s stable operation and its service life. In addition to this, a lamp´s service life is critically dependent on compliance with the starting conditions (preheat current and ignition voltage). Unfavourable starting conditions cause damage to the electrodes every time the lamp is started and thus reduce the lamp´s service life. Furthermore, care should be taken to prevent cross-discharge in the electrode area during preheating, which also shortens lamp service life.
Ballasts are available in electromagnetic or electronic form. Electromagnetic (inductive) ballasts have to be operated in conjunction with starters for lamp ignition and capacitors for blind current compensation. In addition, capacitors for RFI suppression will also be required for certain circuits. Electronic ballasts can be operated without any additional components.
Electronic ballasts (EB)
VS electronic ballasts are designed for mains voltages of 220 V to 240 V and are used to operate fluorescent lamps at high frequency (20 - 50 kHz). The lamps are ignited with an internally generated ignition voltage, thereby removing the need for an external starter. The power factor (l) > 0.95 also removes the need for compensation, unlike with electromagnetic ballasts. The only exceptions are low-output ELXs models, which attain a power factor of 0.6. Luminaires fitted with electronic ballasts are characterised by low energy consumption as they have substantially lower system power than conventional, inductive applications. This is firstly because the lamp consumes less power to achieve the same luminous flux and secondly the internal loss of an electronic ballast only amounts to approx. 8 % to 10 % of the lamp´s output. Furthermore, thanks to their modern circuitry, the power input of VS electronic ballasts remains constant even in the event of mains voltage fluctuations, thus ensuring permanently low energy consumption.
Vossloh-Schwabe electronic ballasts permit a broad range of applications. For instance, VosslohSchwabe´s product range includes many ballast types for multiple lamp operation. These ballasts reduce installation and component costs and thus enable particularly efficient luminaires. Twin-lamp electronic ballasts permit so-called master-slave operation. The lamps of two single-lamp luminaires are operated by a twin-lamp electronic ballast that is built into the so-called master luminaire. The lamp of the slave luminaire is electrically connected to the electronic ballast.
The use of electronic ballasts makes a lighting system both more convenient and efficient to operate:
reduced power consumption (up to 30 %) at undiminished light output
50 % longer service life
stabilised lamp output
overvoltage protection
no stroboscopic effect
flicker-free lamp start
no need for a starter or capacitor
low wiring effort
no radiated electromagnetic interference
low self-heating due to minimal power loss
automatic shutdown of defective lamps
automatic restart once the lamp has been changed
Vossloh-Schwabe electronic ballasts are developed on the basis of the latest technological and component standards and are produced using state-of-the-art technology, whereby consideration is taken of our customers´ quality standards in our quality assurance system.

Vossloh-Schwabe provides the respective electronic ballast family for the most diverse applications:
ELXs ballasts (warm start)
The family of ELXs ballasts forms a perfect alternative to magnetic ballasts. ELXs ballasts have the same fastening hole spacing as standard electromagnetic ballasts. The lamp is ignited after a preheating time (warm start) of 1.5 seconds. These ballasts are available for system outputs (lamp output plus power loss of the electronic ballast) of up to 25 W. The power factor of these ballasts amounts to approx. 0.6. The average service life of these ballasts totals 30,000 hours with a failure rate of ≤ 0.2 % per 1,000 operating hours.
ELXe ballasts (instant start)
With this ballast family, the lamps ignite immediately after connection to the mains voltage by applying an ignition voltage of max. 1,500 V to the gas discharge path of the lamp. The ignition time totals less than 0.2 seconds. As this puts a severe strain on the electrodes, the realistic number of lamp starts is limited to approx. 10,000 ignitions up to the end of the lamp¢¥s service life. For that reason, ELXe ballasts should only be used for applications demanding fewer than five lamp ignitions per day (e.g. in production sites, warehouses or department stores). As there is no need for preheating, ELXe ballasts only require one connection per electrode for lamp operation. This makes them suitable for use in explosion protected luminaires. In addition to this, they are extremely energy efficient as no lamp electrode losses occur. The average service life of these ballasts totals 50,000 hours with a failure rate of ≤ 0.2 % per 1,000 operating hours.
ELXc ballasts (warm start)
ELXc ballasts ensure the lamp is started following a defined lamp electrode preheating period of approx. 1.5 seconds using a fixed ignition voltage. This particularly gentle lamp start makes over 20,000 lamp starts possible. ELXc ballasts should be used for applications with high switching frequencies (e.g. hotels or offices) where energy savings as well as low maintenance costs are desired. The average service life of these ballasts totals 50,000 hours with a failure rate of ≤ 0.2 % per 1,000 operating hours.
ELXd ballasts (dimmable)
These are ELXc ballasts with an additional dimming function that is controlled via an interface fitted to the ballast. The interface of these ballasts can be either analogue (1-10 Volt) or digital (DALI; PUSH); the interface enables lighting to be ideally adjusted to suit the given need. Control components can also be used as long as they comply with the respective standard (appendix to IEC/EN 60929). When using ELXd ballasts in a lighting system, an energy saving of 75 % can be achieved if the control inputs of the ballasts are coupled with movement detectors and light sensors. The average service life of these ballasts totals 50,000 hours with a failure rate of ≤ 0.2 % per 1,000 operating hours.
To guarantee trouble-free operation and a long service life of the various types of electronic ballast, attention should be paid to the regulations and mounting instructions. In addition, the installation instructions for lighting systems must be observed when installing luminaires with electronic ballasts.