Showing posts with label HID. Show all posts
Showing posts with label HID. Show all posts
Wednesday, May 14, 2008
What is HMI lamps
HMI lamps are metal halide lamps with an increased load on the bulb wall and very short electrode gaps to improve luminous efficacy and colour rendering, at the expense however of lamp life. These lamps are ideal for applications such as theatre lighting, endoscopy, filming and TV recordings under daylight conditions (colour temperature
= 6000K).These lamps range in wattage from 200 W to 18 kW.
Friday, May 9, 2008
Pulse ignition systems
For HS, HI and C-HI lamps - PZ 1000 K / PZ 1000 K P20 For high-pressure sodium lamps (HS), metal halide lamps (HI) 35 -1000 W and ceramic discharge tube lamps (C-HI) 35 - 400 W Ignition voltage: 1.8 - 2.3 kV or 4.0 - 5.0 kV, respectively No. of pulses: 2 per mains period Load capacitance: 20 -1000 pF Suitable ballast types: NaHJ ... PZ/PZT with special winding tapping point, whose position is determined by the magnitude of the ignition voltage

For HI lamps - PZI 1000/1 K and PZI 2000/400 V 1.2 kV For metal halide lamps (HI) with an ignition voltage up to 0.9 kV or 1.3 kV, respectively. No. of pulses: 1per mains period Load capacitance: max. 10,000 pF Suitable ballast models: Q...

For HI lamps - PZI 1000/1 K and PZI 2000/400 V 1.2 kV For metal halide lamps (HI) with an ignition voltage up to 0.9 kV or 1.3 kV, respectively. No. of pulses: 1per mains period Load capacitance: max. 10,000 pF Suitable ballast models: Q...
Edison bases are predominantly used for mercury vapour lamps (HM)
Edison bases are predominantly used for mercury vapour lamps (HM)
Lampholders for high-pressure discharge lamps
Metal halide and high-pressure sodium lamps feature extremely different bases, which include RX7s, Fc2, G8.5, GX10, G12, PG12, E27 and E40, depending on whether the lamp is single- or double-ended. All lampholders are subject to the same typical conditions found with discharge lamps: high ignition voltages and temperatures. The high start-up currents deserve particular attention in lampholder design. This is also reflected by the insulation materials, which are usually solid ceramics or heat-resistant plastic (e.g. PPS - polyphenylene sulphide). Depending on the lamp´s requirements (voltage, current, temperature, etc.), silver, nickel and copper alloys with thick nickel coatings are used as conductors. The luminaire regulation IEC 60598-1, in accordance with EN 60598-1, defines the safety requirements with regard to ignition voltages in connection with creepage and air clearance distances.
Special care must be taken to ensure that lampholders are approved for discharge lamps when using high-pressure lamps with E27 and E40 Edison bases. Lamholders that are suitable for this purpose are marked with a maximum value of "5 kV" and comply with the creepage and air clearance distances required by EC 60238 and EN 60238 (VDE 0616 part 1). The lampholder regulations governing special lampholders, IEC 60838-1 and EN 60838-1 (VDE 0616 part 5), apply analogously to all other base systems. The high ignition voltage pulses also place special demands on the conductors. In practice, silicone-insulated conductors with an outer diameter of 3.6 mm have proved suitable for discharge lamps. Silicone-insulated conductors with a glass-silk lining with a diameter of 7 mm should be used for lamps with an immediate hot restart function.
Special care must be taken to ensure that lampholders are approved for discharge lamps when using high-pressure lamps with E27 and E40 Edison bases. Lamholders that are suitable for this purpose are marked with a maximum value of "5 kV" and comply with the creepage and air clearance distances required by EC 60238 and EN 60238 (VDE 0616 part 1). The lampholder regulations governing special lampholders, IEC 60838-1 and EN 60838-1 (VDE 0616 part 5), apply analogously to all other base systems. The high ignition voltage pulses also place special demands on the conductors. In practice, silicone-insulated conductors with an outer diameter of 3.6 mm have proved suitable for discharge lamps. Silicone-insulated conductors with a glass-silk lining with a diameter of 7 mm should be used for lamps with an immediate hot restart function.
Circuit diagrams for high-pressure sodium lamps and metal halide lamps
Superimposed ignition of HS and HI lamps
Pulse ignition of HS and HI lamps
Power reduction of HM lamps
NHT-SDX lamps 100 V/200 V (autotransformer for European voltage)
Mandatory regulations of HID Ballast
DIN VDE 0100
Regulations for the installation of power current facilities with rated voltages of up to 1000 V
EN 60598-1
Luminaires - part 1: general requirements and tests
EN 61347-1
Devices for lamps - part 1: general and safety requirements
EN 61347-2-9
Devices for lamps - part 2 - 9: special requirements for ballasts for discharge lamps (except fluorescent lamps)
EN 60923
Ballasts for discharge lamps - performance requirements
EN 55015
Maximum values and methods of measurement for RFI suppression in electrical lighting installations and similar electrical appliances
EN 61000-3-2
Electromagnetic Compatibility (EMC) - part 3: maximum values - main section part 2: maximum values for mains harmonics (device input current up to and including 16 A per conductor)
EN 61547
Installations for general illumination purposes - EMC immunity requirements
Click on the image to get a PDF-file with the assembly instructions of electronic converters.
Regulations for the installation of power current facilities with rated voltages of up to 1000 V
EN 60598-1
Luminaires - part 1: general requirements and tests
EN 61347-1
Devices for lamps - part 1: general and safety requirements
EN 61347-2-9
Devices for lamps - part 2 - 9: special requirements for ballasts for discharge lamps (except fluorescent lamps)
EN 60923
Ballasts for discharge lamps - performance requirements
EN 55015
Maximum values and methods of measurement for RFI suppression in electrical lighting installations and similar electrical appliances
EN 61000-3-2
Electromagnetic Compatibility (EMC) - part 3: maximum values - main section part 2: maximum values for mains harmonics (device input current up to and including 16 A per conductor)
EN 61547
Installations for general illumination purposes - EMC immunity requirements
Click on the image to get a PDF-file with the assembly instructions of electronic converters.
Power reduction with HS and HM lamps
The lamp wattage can be reduced by operating the ballast at a higher impedance value, higher than the rated value. The lamp manufacturer´s specifications must be observed in doing so to avoid shortening the lamp´s service life. The lamps should be started at the ballast´s rated impedance and only switched down to reduced operation after a period of at least five minutes.
The impedance value can be altered by using an additional ballast (high-effort option) or by using a switchable ballast (low-cost option). These ballast models can be switched using either a modern, time-controlled electronic power reduction switch, which is equipped with an additional control conductor (230 V), or a power reduction switch with a constant incentive rate setting (no control conductor).
The construction of power reduction switches with control conductors differs according to the selected increase in impedance. PW devices are suitable for additional ballasts and PU devices for switchable ballasts.
The impedance value can be altered by using an additional ballast (high-effort option) or by using a switchable ballast (low-cost option). These ballast models can be switched using either a modern, time-controlled electronic power reduction switch, which is equipped with an additional control conductor (230 V), or a power reduction switch with a constant incentive rate setting (no control conductor).
The construction of power reduction switches with control conductors differs according to the selected increase in impedance. PW devices are suitable for additional ballasts and PU devices for switchable ballasts.
Ballasts for HM lamps
Even in the event of major mains fluctuations (94 -106 % of the rated voltage), the ballast must not fall short of the no-load voltage specified by the lamp manufacturer nor exceed a fixed short-circuit current.
The start-up current must be high enough to ensure that at least 90 % of the lamp´s operating voltage is achieved within 15 minutes.
The start-up current must be high enough to ensure that at least 90 % of the lamp´s operating voltage is achieved within 15 minutes.
Electromagnetic ballasts for HI and HS lamps
As the lamp manufacturer´s reference values regarding lamp current and voltage are generally identical for metal halide (HI) and high-pressure sodium lamps (HS) of the same lamp wattage and the impedance values required for the ballast are also identical, the same ballasts can frequently be used for both lamp types. It should be remembered that HI lamps react sensitively to impedance deviations from the rated value with appreciable colour changes. Vossloh-Schwabe ballasts therefore comply with the lamp´s narrower tolerances. Moreover, the maximum peak direct current value must be observed when operating HI lamps. This value is not specified for HS lamps; instead, the maximum stated start-up current must not be exceeded.
In order to keep the temperature of the luminaires and the electrical values of the lamps within tolerable limits, the impedance of the ballasts must remain constant over the entire service life. A so-called service life test provides proof of this requirement having been met.
HI and HS lamps constitute a special case in terms of thermal testing. In rare cases, a safety risk can occur at the end of the service life of lamps fitted with external bulbs. The safety risk is caused by the so-called lamp rectifier effect, which can lead to overheating of ballasts, ignitors, lamphoders and conductors and can therefore destroy the luminaire. Against this background, the luminaire standard EN 60598-1 "luminaires; part 1: general requirements and tests" has been supplemented by tests concerning this safety risk. As a result, since 1September 2002, it has been illegal to market luminaires that do not comply with the new regulations, i.e. that do not limit the degree to which a lamp heats up in the event of this malfunction. Approvals of luminaires according to the old version of EN 60598 are being withdrawn by the testing institutes. The luminaires are tested using an equivalent circuit, whereby the respective resistors must be dimensioned to suit.
In order to keep the temperature of the luminaires and the electrical values of the lamps within tolerable limits, the impedance of the ballasts must remain constant over the entire service life. A so-called service life test provides proof of this requirement having been met.
HI and HS lamps constitute a special case in terms of thermal testing. In rare cases, a safety risk can occur at the end of the service life of lamps fitted with external bulbs. The safety risk is caused by the so-called lamp rectifier effect, which can lead to overheating of ballasts, ignitors, lamphoders and conductors and can therefore destroy the luminaire. Against this background, the luminaire standard EN 60598-1 "luminaires; part 1: general requirements and tests" has been supplemented by tests concerning this safety risk. As a result, since 1September 2002, it has been illegal to market luminaires that do not comply with the new regulations, i.e. that do not limit the degree to which a lamp heats up in the event of this malfunction. Approvals of luminaires according to the old version of EN 60598 are being withdrawn by the testing institutes. The luminaires are tested using an equivalent circuit, whereby the respective resistors must be dimensioned to suit.
Electronic ballasts for HI and C-HI lamps
Electronic ballasts are fitted with all the components required to operate discharge lamps. Furthermore, they safely shut down lamps at the end of their service life to prevent high temperatures from being generated within the luminaires that could influence the service life of the luminaires and components. Vossloh-Schwabe provides electronic ballasts that are equipped with an additional switching contact that makes it possible, for instance, to switch on a light bulb during the dark phase of a discharge lamp.
By adding a strain-relief module, these electronic built-in ballasts turn into independent operating devices that can, for instance, be used as a power unit and can also be installed in intermediate ceilings in this form.
By adding a strain-relief module, these electronic built-in ballasts turn into independent operating devices that can, for instance, be used as a power unit and can also be installed in intermediate ceilings in this form.
Components for discharge lamps
If the electrical current through a discharge lamp is increased, a discharge channel with very high luminous efficiency is created in the discharge chamber; luminous flux and light output increase substantially. The internal pressure of the discharge chamber rises and attains between 1and 10 bar these are so-called high-pressure discharge lamps (general: discharge lamp). The light output and colour rendition of high-pressure lamps vary considerably depending on the lamp family.
Discharge lamps can only be operated with ballasts. Ignitors are additionally required for sodium lamps and metal halide lamps. Furthermore, to compensate blind current when using magnetic ballasts, compensation capacitors must be fitted. The lampholders enable the lamp to be fixed in the luminaire and ensure simple exchange of lamps at the end of their service life. As well as stabilising the lamp´s operating point, ballasts also influence the lamp´s output and luminous flux, the system´s light output, the service life of the lamps as well as the colour temperature of the light
High-pressure sodium lamps (HS lamps)
Metal halide lamps (HI lamps)
Metal halide lamps with a ceramic discharge tube (C-HI lamps)
Mercury vapour lamps (HM lamps)
Low-pressure sodium lamps (LS lamps)
Ballasts can be of either electromagnetic or electronic construction. Unlike with fluorescent lamps, lamp efficiency is not decisively altered by the use of electronic ballasts. In contrast, electronic ballasts lead to a reduction of the inherent losses and thus to an increase in system efficiency. In addition, electronic ballasts ensure gentle lamp operation, which increases the lamp´s service life.
Discharge lamps can only be operated with ballasts. Ignitors are additionally required for sodium lamps and metal halide lamps. Furthermore, to compensate blind current when using magnetic ballasts, compensation capacitors must be fitted. The lampholders enable the lamp to be fixed in the luminaire and ensure simple exchange of lamps at the end of their service life. As well as stabilising the lamp´s operating point, ballasts also influence the lamp´s output and luminous flux, the system´s light output, the service life of the lamps as well as the colour temperature of the light
High-pressure sodium lamps (HS lamps)
Metal halide lamps (HI lamps)
Metal halide lamps with a ceramic discharge tube (C-HI lamps)
Mercury vapour lamps (HM lamps)
Low-pressure sodium lamps (LS lamps)
Ballasts can be of either electromagnetic or electronic construction. Unlike with fluorescent lamps, lamp efficiency is not decisively altered by the use of electronic ballasts. In contrast, electronic ballasts lead to a reduction of the inherent losses and thus to an increase in system efficiency. In addition, electronic ballasts ensure gentle lamp operation, which increases the lamp´s service life.