LED stands for “Light Emitting Diode” and is a kind of semiconductor, which emits light when electrified.
In other words, the LED emits light by itself and requires no filaments like incandescent lamps, which is fundamentally different from conventional light sources.
LED has long life span, however, deterioration of the sealing materials will reduce its light efficiency.
A Light Emitting Diode (LED) light source is a semiconductor. Light emitting diodes (LEDs) are used as indicator lamps in many devices, and are increasingly used for lighting. Introduced as an electronic component in the handy LED.
Researchers from around the world gathered at the Materials Research Society fall meeting in Boston last week to discuss the progress they're making in using quantum dots to enhance the color and efficiency of light-emitting diodes (LEDs). Today's white-light LEDs consist of a blue-emitting LED coated with a phosphor that is excited by the LED and emits a yellow or orange light. The combination of blue and yellow produces a cold white light lacking in red photons,
Factors influencing the deterioration of packaging resin material: -
Heat
High ambient temperature and generated heat by high electric current give rise to resin deterioration.
Light
Bigger spectrum energy increases resin deterioration.
Blue spectrum has bigger energy compared with red spectrum, therefore life span of blue color LED is shorter than others.
light-emitting diode n. LED. I-V diagram for a diode an LED will begin to emit light when the on-voltage XLamp XP-G LED chip emitting Cool White light) and are being (.... quot; led light bulbs led lamps -- Provider of led light bulbs, LED components and lighting technology. LC LED offers Light Emitting Diode (L.E.D.) base systems solution for your every day consumer (.... lightemitting diodes led learning activity -- Copyright © Wisc-Online. Title: Light-Emitting Diodes (LED) Author: Patrick Hoppe. Developer: Chad Blohowiak. Facebook. Now Available - Click Here to Purchase (.... special report business of green small british company develops -- Light emitting diode, or LED, lights are becoming popular because of their low energy use, long life and versatility, yet they present several problems — ranging from a risk of (.... light emitting diodes -- A Light Emitting Diode (LED) light source is a semiconductor. Light emitting diodes (LEDs) are used as indicator lamps in many devices, and are increasingly used for lighting. (.... light emitting diodes led -- Basic car audio technical information with plenty of graphics. This site starts with the most basic information so that everyone will be able to understand the more advanced topics (.... lightemittingdiodesdotorg home page -- Buy the book Light Emitting Diodes by E. F. Schubert: 2006 LED book pictures (80 MB).pdf Homepage of E. Fred Schubert National Compound Semiconductor Roadmap Compund (.... led wikipedia the free encyclopedia -- LEd (formerly LaTeX Editor) is a TeX / LaTeX editing software working under Microsoft Windows. It is a freeware product. See also. Comparison of TeX editors (.... howstuffworks quot;how light emitting diodes workquot; -- Light emitting diodes form the numbers on digital clocks, send data from remote controls and light up traffic signals. Find out how LEDs work. (.... led light emitting diode lights light bulbs etc inc -- Light Bulbs Etc, Inc. carries LED (Light Emitting Diode) Lights, including LED (Light Emitting Diode) Night Lights. These LED (Light Emitting Diode) Night Lights are low cost (.... lightemitting diode wikipedia the free encyclopedia -- A light-emitting diode (LED) (pronounced /ˌɛl.iːˈdiː/ [1], or just /lɛd/) is a semiconductor light source. LEDs are used as indicator lamps in many devices,
Thursday, December 10, 2009
Wednesday, May 14, 2008
what is Illuminance E ?
The unit of measurement is the lux [lx]: E = F / A F = luminous flux in lumenensA = area illuminated in m2 Illuminance E is the ratio between the luminous flux and the area to be illuminated. An illuminance of 1 lx occurs when a luminous flux of 1 lm falls evenly on an area of 1 m². Based on the definitions for illuminance luminous intensity and solid angle W = A/r2, we obtain the following formula for illuminance: E = I / r2Photometric inverse square law r = distance of the light source to the object in mA = area illuminated in m2I = luminous intensity in Candela It is assumed that the light falls perpendicular to the surface it illuminates. If the surface is at an angle a then E = I/r2 must be multiplied by cos a.
What is HMI lamps
HMI lamps are metal halide lamps with an increased load on the bulb wall and very short electrode gaps to improve luminous efficacy and colour rendering, at the expense however of lamp life. These lamps are ideal for applications such as theatre lighting, endoscopy, filming and TV recordings under daylight conditions (colour temperature
= 6000K).These lamps range in wattage from 200 W to 18 kW.
what is Halogen cycle
Halogen cycle The main characteristics of an incandescent lamp, namely its luminous efficacy and service life, are determined to a large extent by the filament temperature. The higher the filament temperature, the higher the luminous efficacy but the shorter the life of the lamp. This reduction in the life of the lamp is a consequence of the rate at which tungsten evaporates from the filament. This rate increases rapidly with increasing temperature. Not only does it blacken the inside of the bulb, it causes the filament ultimately to burn out. This blackening of the bulb can be effectively countered by adding halogens to the filler gas to prevent evaporated tungsten from depositing on the bulb wall by a "halogen cycle process". The tungsten that evaporates from the filament during normal operation migrates towards the bulb wall by diffusion or thermal convection In the temperature region <1400>1400 K) where they dissociate back to tungsten and halogen, leaving the halogen to repeat the cycle. Some of the tungsten is transported back to the filament, but not to its original location. The "normal halogen cycle" therefore merely prevents the bulb from blackening, it does not extend the life of the lamp. The lamp comes to the end of its life when the filament melts at one of its hot spots.
Friday, May 9, 2008
Pulse ignition systems
For HS, HI and C-HI lamps - PZ 1000 K / PZ 1000 K P20 For high-pressure sodium lamps (HS), metal halide lamps (HI) 35 -1000 W and ceramic discharge tube lamps (C-HI) 35 - 400 W Ignition voltage: 1.8 - 2.3 kV or 4.0 - 5.0 kV, respectively No. of pulses: 2 per mains period Load capacitance: 20 -1000 pF Suitable ballast types: NaHJ ... PZ/PZT with special winding tapping point, whose position is determined by the magnitude of the ignition voltage

For HI lamps - PZI 1000/1 K and PZI 2000/400 V 1.2 kV For metal halide lamps (HI) with an ignition voltage up to 0.9 kV or 1.3 kV, respectively. No. of pulses: 1per mains period Load capacitance: max. 10,000 pF Suitable ballast models: Q...

For HI lamps - PZI 1000/1 K and PZI 2000/400 V 1.2 kV For metal halide lamps (HI) with an ignition voltage up to 0.9 kV or 1.3 kV, respectively. No. of pulses: 1per mains period Load capacitance: max. 10,000 pF Suitable ballast models: Q...
Edison bases are predominantly used for mercury vapour lamps (HM)
Edison bases are predominantly used for mercury vapour lamps (HM)
Lampholders for high-pressure discharge lamps
Metal halide and high-pressure sodium lamps feature extremely different bases, which include RX7s, Fc2, G8.5, GX10, G12, PG12, E27 and E40, depending on whether the lamp is single- or double-ended. All lampholders are subject to the same typical conditions found with discharge lamps: high ignition voltages and temperatures. The high start-up currents deserve particular attention in lampholder design. This is also reflected by the insulation materials, which are usually solid ceramics or heat-resistant plastic (e.g. PPS - polyphenylene sulphide). Depending on the lamp´s requirements (voltage, current, temperature, etc.), silver, nickel and copper alloys with thick nickel coatings are used as conductors. The luminaire regulation IEC 60598-1, in accordance with EN 60598-1, defines the safety requirements with regard to ignition voltages in connection with creepage and air clearance distances.
Special care must be taken to ensure that lampholders are approved for discharge lamps when using high-pressure lamps with E27 and E40 Edison bases. Lamholders that are suitable for this purpose are marked with a maximum value of "5 kV" and comply with the creepage and air clearance distances required by EC 60238 and EN 60238 (VDE 0616 part 1). The lampholder regulations governing special lampholders, IEC 60838-1 and EN 60838-1 (VDE 0616 part 5), apply analogously to all other base systems. The high ignition voltage pulses also place special demands on the conductors. In practice, silicone-insulated conductors with an outer diameter of 3.6 mm have proved suitable for discharge lamps. Silicone-insulated conductors with a glass-silk lining with a diameter of 7 mm should be used for lamps with an immediate hot restart function.
Special care must be taken to ensure that lampholders are approved for discharge lamps when using high-pressure lamps with E27 and E40 Edison bases. Lamholders that are suitable for this purpose are marked with a maximum value of "5 kV" and comply with the creepage and air clearance distances required by EC 60238 and EN 60238 (VDE 0616 part 1). The lampholder regulations governing special lampholders, IEC 60838-1 and EN 60838-1 (VDE 0616 part 5), apply analogously to all other base systems. The high ignition voltage pulses also place special demands on the conductors. In practice, silicone-insulated conductors with an outer diameter of 3.6 mm have proved suitable for discharge lamps. Silicone-insulated conductors with a glass-silk lining with a diameter of 7 mm should be used for lamps with an immediate hot restart function.
Circuit diagrams for high-pressure sodium lamps and metal halide lamps
Superimposed ignition of HS and HI lamps
Pulse ignition of HS and HI lamps
Power reduction of HM lamps
NHT-SDX lamps 100 V/200 V (autotransformer for European voltage)
Mandatory regulations of HID Ballast
DIN VDE 0100
Regulations for the installation of power current facilities with rated voltages of up to 1000 V
EN 60598-1
Luminaires - part 1: general requirements and tests
EN 61347-1
Devices for lamps - part 1: general and safety requirements
EN 61347-2-9
Devices for lamps - part 2 - 9: special requirements for ballasts for discharge lamps (except fluorescent lamps)
EN 60923
Ballasts for discharge lamps - performance requirements
EN 55015
Maximum values and methods of measurement for RFI suppression in electrical lighting installations and similar electrical appliances
EN 61000-3-2
Electromagnetic Compatibility (EMC) - part 3: maximum values - main section part 2: maximum values for mains harmonics (device input current up to and including 16 A per conductor)
EN 61547
Installations for general illumination purposes - EMC immunity requirements
Click on the image to get a PDF-file with the assembly instructions of electronic converters.
Regulations for the installation of power current facilities with rated voltages of up to 1000 V
EN 60598-1
Luminaires - part 1: general requirements and tests
EN 61347-1
Devices for lamps - part 1: general and safety requirements
EN 61347-2-9
Devices for lamps - part 2 - 9: special requirements for ballasts for discharge lamps (except fluorescent lamps)
EN 60923
Ballasts for discharge lamps - performance requirements
EN 55015
Maximum values and methods of measurement for RFI suppression in electrical lighting installations and similar electrical appliances
EN 61000-3-2
Electromagnetic Compatibility (EMC) - part 3: maximum values - main section part 2: maximum values for mains harmonics (device input current up to and including 16 A per conductor)
EN 61547
Installations for general illumination purposes - EMC immunity requirements
Click on the image to get a PDF-file with the assembly instructions of electronic converters.
Power reduction with HS and HM lamps
The lamp wattage can be reduced by operating the ballast at a higher impedance value, higher than the rated value. The lamp manufacturer´s specifications must be observed in doing so to avoid shortening the lamp´s service life. The lamps should be started at the ballast´s rated impedance and only switched down to reduced operation after a period of at least five minutes.
The impedance value can be altered by using an additional ballast (high-effort option) or by using a switchable ballast (low-cost option). These ballast models can be switched using either a modern, time-controlled electronic power reduction switch, which is equipped with an additional control conductor (230 V), or a power reduction switch with a constant incentive rate setting (no control conductor).
The construction of power reduction switches with control conductors differs according to the selected increase in impedance. PW devices are suitable for additional ballasts and PU devices for switchable ballasts.
The impedance value can be altered by using an additional ballast (high-effort option) or by using a switchable ballast (low-cost option). These ballast models can be switched using either a modern, time-controlled electronic power reduction switch, which is equipped with an additional control conductor (230 V), or a power reduction switch with a constant incentive rate setting (no control conductor).
The construction of power reduction switches with control conductors differs according to the selected increase in impedance. PW devices are suitable for additional ballasts and PU devices for switchable ballasts.
Ballasts for HM lamps
Even in the event of major mains fluctuations (94 -106 % of the rated voltage), the ballast must not fall short of the no-load voltage specified by the lamp manufacturer nor exceed a fixed short-circuit current.
The start-up current must be high enough to ensure that at least 90 % of the lamp´s operating voltage is achieved within 15 minutes.
The start-up current must be high enough to ensure that at least 90 % of the lamp´s operating voltage is achieved within 15 minutes.
Electromagnetic ballasts for HI and HS lamps
As the lamp manufacturer´s reference values regarding lamp current and voltage are generally identical for metal halide (HI) and high-pressure sodium lamps (HS) of the same lamp wattage and the impedance values required for the ballast are also identical, the same ballasts can frequently be used for both lamp types. It should be remembered that HI lamps react sensitively to impedance deviations from the rated value with appreciable colour changes. Vossloh-Schwabe ballasts therefore comply with the lamp´s narrower tolerances. Moreover, the maximum peak direct current value must be observed when operating HI lamps. This value is not specified for HS lamps; instead, the maximum stated start-up current must not be exceeded.
In order to keep the temperature of the luminaires and the electrical values of the lamps within tolerable limits, the impedance of the ballasts must remain constant over the entire service life. A so-called service life test provides proof of this requirement having been met.
HI and HS lamps constitute a special case in terms of thermal testing. In rare cases, a safety risk can occur at the end of the service life of lamps fitted with external bulbs. The safety risk is caused by the so-called lamp rectifier effect, which can lead to overheating of ballasts, ignitors, lamphoders and conductors and can therefore destroy the luminaire. Against this background, the luminaire standard EN 60598-1 "luminaires; part 1: general requirements and tests" has been supplemented by tests concerning this safety risk. As a result, since 1September 2002, it has been illegal to market luminaires that do not comply with the new regulations, i.e. that do not limit the degree to which a lamp heats up in the event of this malfunction. Approvals of luminaires according to the old version of EN 60598 are being withdrawn by the testing institutes. The luminaires are tested using an equivalent circuit, whereby the respective resistors must be dimensioned to suit.
In order to keep the temperature of the luminaires and the electrical values of the lamps within tolerable limits, the impedance of the ballasts must remain constant over the entire service life. A so-called service life test provides proof of this requirement having been met.
HI and HS lamps constitute a special case in terms of thermal testing. In rare cases, a safety risk can occur at the end of the service life of lamps fitted with external bulbs. The safety risk is caused by the so-called lamp rectifier effect, which can lead to overheating of ballasts, ignitors, lamphoders and conductors and can therefore destroy the luminaire. Against this background, the luminaire standard EN 60598-1 "luminaires; part 1: general requirements and tests" has been supplemented by tests concerning this safety risk. As a result, since 1September 2002, it has been illegal to market luminaires that do not comply with the new regulations, i.e. that do not limit the degree to which a lamp heats up in the event of this malfunction. Approvals of luminaires according to the old version of EN 60598 are being withdrawn by the testing institutes. The luminaires are tested using an equivalent circuit, whereby the respective resistors must be dimensioned to suit.
Electronic ballasts for HI and C-HI lamps
Electronic ballasts are fitted with all the components required to operate discharge lamps. Furthermore, they safely shut down lamps at the end of their service life to prevent high temperatures from being generated within the luminaires that could influence the service life of the luminaires and components. Vossloh-Schwabe provides electronic ballasts that are equipped with an additional switching contact that makes it possible, for instance, to switch on a light bulb during the dark phase of a discharge lamp.
By adding a strain-relief module, these electronic built-in ballasts turn into independent operating devices that can, for instance, be used as a power unit and can also be installed in intermediate ceilings in this form.
By adding a strain-relief module, these electronic built-in ballasts turn into independent operating devices that can, for instance, be used as a power unit and can also be installed in intermediate ceilings in this form.
Components for discharge lamps
If the electrical current through a discharge lamp is increased, a discharge channel with very high luminous efficiency is created in the discharge chamber; luminous flux and light output increase substantially. The internal pressure of the discharge chamber rises and attains between 1and 10 bar these are so-called high-pressure discharge lamps (general: discharge lamp). The light output and colour rendition of high-pressure lamps vary considerably depending on the lamp family.
Discharge lamps can only be operated with ballasts. Ignitors are additionally required for sodium lamps and metal halide lamps. Furthermore, to compensate blind current when using magnetic ballasts, compensation capacitors must be fitted. The lampholders enable the lamp to be fixed in the luminaire and ensure simple exchange of lamps at the end of their service life. As well as stabilising the lamp´s operating point, ballasts also influence the lamp´s output and luminous flux, the system´s light output, the service life of the lamps as well as the colour temperature of the light
High-pressure sodium lamps (HS lamps)
Metal halide lamps (HI lamps)
Metal halide lamps with a ceramic discharge tube (C-HI lamps)
Mercury vapour lamps (HM lamps)
Low-pressure sodium lamps (LS lamps)
Ballasts can be of either electromagnetic or electronic construction. Unlike with fluorescent lamps, lamp efficiency is not decisively altered by the use of electronic ballasts. In contrast, electronic ballasts lead to a reduction of the inherent losses and thus to an increase in system efficiency. In addition, electronic ballasts ensure gentle lamp operation, which increases the lamp´s service life.
Discharge lamps can only be operated with ballasts. Ignitors are additionally required for sodium lamps and metal halide lamps. Furthermore, to compensate blind current when using magnetic ballasts, compensation capacitors must be fitted. The lampholders enable the lamp to be fixed in the luminaire and ensure simple exchange of lamps at the end of their service life. As well as stabilising the lamp´s operating point, ballasts also influence the lamp´s output and luminous flux, the system´s light output, the service life of the lamps as well as the colour temperature of the light
High-pressure sodium lamps (HS lamps)
Metal halide lamps (HI lamps)
Metal halide lamps with a ceramic discharge tube (C-HI lamps)
Mercury vapour lamps (HM lamps)
Low-pressure sodium lamps (LS lamps)
Ballasts can be of either electromagnetic or electronic construction. Unlike with fluorescent lamps, lamp efficiency is not decisively altered by the use of electronic ballasts. In contrast, electronic ballasts lead to a reduction of the inherent losses and thus to an increase in system efficiency. In addition, electronic ballasts ensure gentle lamp operation, which increases the lamp´s service life.
Thursday, May 8, 2008
Fluorescent lamps
Fluorescent lamps are low pressure gas discharge lamps in which the invisible UV radiation generated by the discharge is converted into visible radiation (i.e. light) with the aid of phosphors. (Principle of fluorescence) There are tubular, ring-shaped and U-shaped fluorescent lamps and also compact fluorescent lamps. The tube diameter is often expressed in eighths of an inch (e.g. T5 = 5/8'' = 16 mm). In the lamp catalogues, diameters are also given in millimetres (e.g. 16 mm for T5 lamps). Most lamps are internationally standardized. Like all discharge lamps, fluorescent lamps cannot be operated directly on mains voltage because of their negative internal resistance characteristics. Suitable control gear between the mains supply and the lamp, limits and control the lamp current and ensures reliable starting under specific conditions. Fluorescent lamps have various operating modes, depending on the way in which the electrodes are brought up to the temperature:
Current-controlled preheating in switch-start mode, preferred in countries with a high mains voltage (200 V or more). Used in most electronic control gear (ECG).
Voltage-controlled preheating with additional transformer for "rapid start" mode.
No preheating (cold start, used for example with slimline lamps). This type of starting reduces the lamp life more than any other type and is therefore not recommended for systems with frequent on/off switching.
Electronic control gear (ECG) converts the mains frequency into a high frequency supply in the region of 35 to 50 kHz. As a result, the 100 Hz flicker that may appear as a stroboscopic effect, for example with rotating machines, is much less noticeable or virtually eliminated. Another advantage of ECG operation is the additional energy savings of around 25% for the same luminous flux, comprising:
10% high luminous efficacy from the fluorescent lamp operating at a high frequency
Much lower losses in the ECG (less than half) compared with conventional control gear (CCG) Dimming Dimmable ECGs make use of the property of a choke whereby its inductance increases as the frequency increases. As the operating frequency is made to increase, the choke connected in series with the lamp supplies a progressively lower current. The frequency is controlled via a 1-10 V or a DALI interface. The dimmable ECGs must also ensure that in the dimmed state the cathodes are constantly heated so that they continue to emit electrons even when the lamp current is at a low level. Lamp life and resistance to switching transients If fluorescent lamps are operated with CCGs and conventional starters their life is shortened considerably as the frequency of on/off switching increases. The same phenomenon can be observed with cold-start ECGs, which have the ability of starting fluorescent lamps instantly. However, the rapid transition from glow discharge temperature to emission temperature seriously damages the cathodes, so frequent switching cycles reduce the life of fluorescent lamps. Warm start control gear behave in a completely different way. In this case, the cathodes are heated before ignition, which virtually eliminates switching damage to the cathodes. The associated delay in ignition, of around a second is not a serious inconvenience. Thermal behaviour The physical properties of fluorescent lamps depend on their ambient temperature. This in turn depends on the characteristic temperature sensitivity of the mercury vapour pressure in the lamp. At low temperatures it is too low so there are too few atoms that can be excited. At excessively high temperatures the high vapour pressure results increasingly in self-absorption of the generated UV radiation. The lamps achieve their maximum luminous output at an ambient temperature of approx. 25°C. In the case of T5 lamps with a tube diameter of 16mm (FH®, FQ®) the rated luminous flux is specified at 25°C, as with other fluorescent lamps but their maximum luminous flux is achieved at an ambient temperature of 33°C to 37°C. In other words, one advantage of T5 lamps is the higher light output from ‘hot’ compact luminaires.
Current-controlled preheating in switch-start mode, preferred in countries with a high mains voltage (200 V or more). Used in most electronic control gear (ECG).
Voltage-controlled preheating with additional transformer for "rapid start" mode.
No preheating (cold start, used for example with slimline lamps). This type of starting reduces the lamp life more than any other type and is therefore not recommended for systems with frequent on/off switching.
Electronic control gear (ECG) converts the mains frequency into a high frequency supply in the region of 35 to 50 kHz. As a result, the 100 Hz flicker that may appear as a stroboscopic effect, for example with rotating machines, is much less noticeable or virtually eliminated. Another advantage of ECG operation is the additional energy savings of around 25% for the same luminous flux, comprising:
10% high luminous efficacy from the fluorescent lamp operating at a high frequency
Much lower losses in the ECG (less than half) compared with conventional control gear (CCG) Dimming Dimmable ECGs make use of the property of a choke whereby its inductance increases as the frequency increases. As the operating frequency is made to increase, the choke connected in series with the lamp supplies a progressively lower current. The frequency is controlled via a 1-10 V or a DALI interface. The dimmable ECGs must also ensure that in the dimmed state the cathodes are constantly heated so that they continue to emit electrons even when the lamp current is at a low level. Lamp life and resistance to switching transients If fluorescent lamps are operated with CCGs and conventional starters their life is shortened considerably as the frequency of on/off switching increases. The same phenomenon can be observed with cold-start ECGs, which have the ability of starting fluorescent lamps instantly. However, the rapid transition from glow discharge temperature to emission temperature seriously damages the cathodes, so frequent switching cycles reduce the life of fluorescent lamps. Warm start control gear behave in a completely different way. In this case, the cathodes are heated before ignition, which virtually eliminates switching damage to the cathodes. The associated delay in ignition, of around a second is not a serious inconvenience. Thermal behaviour The physical properties of fluorescent lamps depend on their ambient temperature. This in turn depends on the characteristic temperature sensitivity of the mercury vapour pressure in the lamp. At low temperatures it is too low so there are too few atoms that can be excited. At excessively high temperatures the high vapour pressure results increasingly in self-absorption of the generated UV radiation. The lamps achieve their maximum luminous output at an ambient temperature of approx. 25°C. In the case of T5 lamps with a tube diameter of 16mm (FH®, FQ®) the rated luminous flux is specified at 25°C, as with other fluorescent lamps but their maximum luminous flux is achieved at an ambient temperature of 33°C to 37°C. In other words, one advantage of T5 lamps is the higher light output from ‘hot’ compact luminaires.
product of illuminance and time
Unit of measurement: lux second [lx s]Exposure H is defined as the product of illuminance and time (at constant illuminance).H = E * t E = illuminance (in lx)t = time (in seconds)Exposure meters are used in photography to determine the ideal exposure time for a given illuminance. Exposure is also an important factor in assessing safe display times for light-sensitive exhibits in museums.
Energy Label
According to EU Directive 92/75/EEC, household lamps operated on main voltage (incandescent lamps and fluorescent lamps with integrated control gear) and household fluorescent lamps (including single and double-ended lamps without integrated control gear) must be marked on their packaging with an energy label indicating their energy efficiency.The light sources are classified in energy efficiency classes A (very efficient) to G (inefficient).
Emergency lighting
There are two types of emergency lighting - standby lighting and safety lighting. Standby lighting takes over the functions of the normal lighting system if the power supply to that system fails so that essential work can continue. In most cases, standby power generators are used and these then supply power to the normal luminaires. The generators must guarantee at least 10% of the illuminance recommended for the activity. There are three types of safety lighting:
Safety lighting for escape routes; safe evacuation calls for a minimum illuminance of >1 lx at a height of 0.2 m, with a uniformity ratio of 1:40.
Escape lighting as minimum background lighting to enable people to reach emergency exits in large rooms.
Safety lighting for hazardous workplaces (near machines with moving parts) if failure of the normal lighting system presents an immediate risk of an accident or injury.
Safety lighting for escape routes; safe evacuation calls for a minimum illuminance of >1 lx at a height of 0.2 m, with a uniformity ratio of 1:40.
Escape lighting as minimum background lighting to enable people to reach emergency exits in large rooms.
Safety lighting for hazardous workplaces (near machines with moving parts) if failure of the normal lighting system presents an immediate risk of an accident or injury.
Monday, May 5, 2008
Disposal of old lamps
Disposal of old lamps and electronic control gear
Disposal of incandescent lampsIncandescent lamps consist of glass and metal. They do not contain any materials that will harm the environment so they can be simply thrown away with the household refuse. They should not be placed in containers for recycled glass, however, because the glass used for these lamps is not the same as the glass used for bottles. Tungsten-halogen lamps contain very small quantities of halogens and halogen-hydrogen compounds, but the amounts are insignificant (only a few millionths of a gram). Even several lamps together do not present any risk to people or the environment. The lamps can therefore be thrown away with household waste.Disposal of discharge lampsFluorescent tubes, compact fluorescent lamps, high pressure mercury, sodium and metal halide lamps all contain small quantities of mercury.These lamps can be recycled and the mercury recovered, but they can also be disposed of to special land-fill sites for mercury containing waste (seek advice from the Environment department of the local authority)Electronic control gearECGs do not contain any material that will harm the environment but they do contain recycable electronic components so they should be disposed of as electronic waste.
Disposal of incandescent lampsIncandescent lamps consist of glass and metal. They do not contain any materials that will harm the environment so they can be simply thrown away with the household refuse. They should not be placed in containers for recycled glass, however, because the glass used for these lamps is not the same as the glass used for bottles. Tungsten-halogen lamps contain very small quantities of halogens and halogen-hydrogen compounds, but the amounts are insignificant (only a few millionths of a gram). Even several lamps together do not present any risk to people or the environment. The lamps can therefore be thrown away with household waste.Disposal of discharge lampsFluorescent tubes, compact fluorescent lamps, high pressure mercury, sodium and metal halide lamps all contain small quantities of mercury.These lamps can be recycled and the mercury recovered, but they can also be disposed of to special land-fill sites for mercury containing waste (seek advice from the Environment department of the local authority)Electronic control gearECGs do not contain any material that will harm the environment but they do contain recycable electronic components so they should be disposed of as electronic waste.
Subscribe to: